These commands are especially important for large libraries. The "beast" I'm testing with has the following configuration:
Library Element Summary:
Medium Transport Elements: 4 Empty: 4 Full: 0 Address: 1
Import/Export Elements: 2 Empty: 2 Full: 0 Address: 64
Storage Elements: 792 Empty: 720 Full: 72 Address: 256
Data Transfer Elements: 9 Empty: 5 Full: 4 Address: 128
Cleaning Cartridges: 0
NOTE: This work is provided by the Data Products Group, managed by Charlie Newfell. These changes are not currently part of the Tru64 release.
Send mail to admin of this page: Robin.Miller@compaq.com
To Robin's home page.
Last modified: March 4th, 2000
tru64% scu show version
--> Date: March 4th, 2000, Version: V4.0x, Author: Robin T. Miller <--
tru64%
tru64% scu
scu> sbtl 1 0 0
Device: TL800, Bus: 1, Target: 0, Lun: 0, Type: Medium Changer
scu> show elements status empty
Element Transport Exception Element Volume
Address Status State Type Tags
------- --------- --------- ------- ------
Transport 0: 0 Empty Normal MT
Slot 8: 9 Empty Normal ST
Drive 0: 240 Empty Normal DT
(Serial Number) CX742S3311
Drive 1: 241 Empty Normal DT
(Serial Number) JF71503116
scu> show elements status full
Element Transport Exception Element Volume
Address Status State Type Tags
------- --------- --------- ------- ------
Slot 0: 1 Full Normal ST BPZ755
Slot 1: 2 Full Normal ST BPZ754
Slot 2: 3 Full Normal ST BPZ750
Slot 3: 4 Full Normal ST CLN900
Slot 4: 5 Full Normal ST BPZ751
Slot 5: 6 Full Normal ST BPZ756
Slot 6: 7 Full Normal ST BPZ752
Slot 7: 8 Full Normal ST CLN901
Slot 9: 10 Full Normal ST BPZ753
scu> show element address 241
Element Transport Exception Element Volume
Address Status State Type Tags
------- --------- --------- ------- ------
Drive 1: 241 Empty Normal DT
(Serial Number) JF71503116
scu>
scu> exit
tru64%
tru64% scu
scu> sbtl 1 0 0
Device: TL800, Bus: 1, Target: 0, Lun: 0, Type: Medium Changer
scu> set sense full
scu> set width 80
scu> show element tag Robin
Device/Command Information:
Device Name/Type: TL800 (Medium Changer)
Nexus Information: Bus 1, Target 0, Lun 0
Erroring Command: send volume tag
Command Descriptor Block: b6 00 00 00 00 04 00 00 00 28 00 00
Requested Transfer Length: 40
Actual Transfer Length: 0
Data Bytes Sent: 52 6f 62 69 6e 20 20 20 20 20 20 20
20 20 20 20 20 20 20 20 20 20 20 20
20 20 20 20 20 20 20 20 00 00 00 00
00 00 00 00
Command Timeout: 300 seconds
Request Sense Information:
Error Code: 0x70 (Current Error)
Valid Bit: 0
Segment Number: 0
Sense Key: 0x5 (ILLEGAL REQUEST - Illegal request or CDB parameter)
Illegal Length: 0
End Of Media: 0
File Mark: 0
Information Field: 0
Additional Sense Length: 20
Command Specific Information: 0
Additional Sense Code/Qualifier: (0x24, 0) = Invalid field in CDB
Field Replaceable Unit Code: 0
Bit Pointer to Field in Error: 0x4 (valid, bit 5)
Error Field Command/Data (C/D): 0x1 (Illegal parameter in CDB bytes)
Byte Pointer to Field in Error: 0x5 (byte 6)
Additional Sense Bytes: 00 00 00 00 00 00 00 00 00 00
scu>
tru64% scu sbtl 1 0 0 set sense full tur
scu: 'test unit ready' failed on device 'TL800' at nexus [1/0/0]
scu: [1/0/0] CAM CCB function 'XPT_SCSI_IO' failed,
CAM status = CAM_CMD_TIMEOUT (0xb) - Command timed out
The command timeout was set to 180 seconds
tru64%
tru64% scu
scu> sbtl 1 0 0
Device: TL800, Bus: 1, Target: 0, Lun: 0, Type: Medium Changer
scu> sw /dev/rmt0h
Switching to device entry /dev/rmt0h (TZ89)...
scu> pwd
Device: TZ89, Bus: 1, Target: 5, Lun: 0, Type: Sequential Access
scu> sw
Switching to device entry [1/0/0] (TL800)...
scu> pwd
Device: TL800, Bus: 1, Target: 0, Lun: 0, Type: Medium Changer
scu>