Intel(R) Server Platforms SE7520JR2 BMC RELEASE NOTES
=============================================================================
INTEL Enterprise Platform & Services Marketing
Intel Corporation
2111 N.E. 25th Avenue, Hillsboro, OR 97124 USA
=============================================================================
DATE:		April 4, 2006
TO:		Intel(R) server platform SE7520JR2 customers
SUBJECT:	BMC(R) 0.52 Release Notes
=============================================================================
                               LEGAL INFORMATION
=============================================================================
Information in this document is provided in connection with Intel products. 
No license, express or implied, by estoppel or otherwise, to any intellectual 
property rights is granted by this document. Except as provided in Intel's 
Terms and Conditions of Sale for such products, Intel assumes no liability 
whatsoever, and Intel disclaims any express or implied warranty, relating to 
sale and/or use of Intel products including liability or warranties relating 
to fitness for a particular purpose, merchantability, or infringement of any 
patent, copyright or other intellectual property right. Intel Corporation may 
have patents or pending patent applications, trademarks, copyrights, or other 
intellectual property rights that relate to the presented subject matter.  
The furnishing of documents and other materials and information does not 
provide any license, express or implied, by estoppel or otherwise, to any 
such patents, trademarks, copyrights, or other intellectual property rights.  
Intel products are not intended for use in medical, life saving, or life 
sustaining applications. Intel may make changes to specifications and product 
descriptions at any time, without notice.

Intel is a registered trademark of Intel Corporation. 

*Other names and brands are the property of their respective owners.

Copyright (c) 2006 Intel Corporation.

=============================================================================
                              ABOUT THIS RELEASE
=============================================================================
REVISION INFORMATION RETURNED BY GET DEVICE ID COMMAND:

Operational mode:	v00.52
Flash update mode:	v00.11
PIA data:		v00.61 {Hex value=3D}
Manufacturer ID:	0x000157 (Intel)
Product ID:		0x0022 (SE7520JR2)

Checksum Information:
Operational Code
  Region:		0x00030000 -> 0x000dcc46
  Checksum:		0x0f07

Boot Block
  Region:		 0x00000000 -> 0x00003052
  Checksum:		 0x5d7a


=============================================================================
			SYSTEM HARDWARE REQUIREMENTS/REVISIONS
=============================================================================
Intel(R) Management Module(IMM):
  - Advanced Edition PBA C44973-405 or higher with BMC 0.23 or higher
    installed.

  - Professional Edition PBA C46194-301 or higher with BMC 0.23 or higher
    installed.

Advanced Edition NIC board (GCM):
  PBA C44941-201 (or later)

Server Board SE7520JR2 with the following PBA revisions (or higher):
  C53659-301 
  C53660-404
  C53661-601
  C53662-503

=============================================================================
		       SYSTEM SOFTWARE REQUIREMENTS/REVISIONS
=============================================================================
- SE7520JR BIOS revision:
  SE7520JR22.86B.P.05.00.0067.111820041003 (or later) 
  Any BIOS version prior to these will cause the BMC serial channel to not
  function properly.

- SE7520JR2 FRU/SDR package:
  JR-6.6.B or later

- PC87431M mini-Baseboard Management Controller (mBMC) from National Semiconductor:
  Revision 2.40
 
- Firmware revisions on the Advanced Edition IMM card:
  FPGA : rev 47 (or later)
  EDID: rev 04
  Any version prior to these will cause the Keyboard and mouse to become
  non-functional.
  The KVM viewer application will also not function properly with earlier
  FPGA versions.

=============================================================================
                         IMPORTANT INSTALLATION NOTES
=============================================================================
- The following files are necessary to update the firmware:
  Run.bat	- Batch file used to update the firmware
  7520JR52.hex	- BMC 0.52 firmware hex file for the SE7520JR2 platform
  FWPIAUpd.exe	- DOS utility to program firmware hex file into the flash device
		  Prior versions of this utility will not work with this FW

Executing the fwpiaupd utility with your own command switches is unsupported 
and may leave your baseboard in a non-operational state! Please use the
provided batch file to update the firmware.

Executing the batch file can be done from any media (Hard disk, USB disk-on-key,
shared network drive or floppy).

BMC 0.23 or later must be preinstalled.
If this is not the case, please update the IMM firmware to BMC 0.23 before
updating to this release.

The boot block has been changed with the BMC 0.31 release but it is not
required for this release. The batch file provided with this BMC package
does not update the boot block.

=============================================================================
                         INSTALLATION PROCEDURE
=============================================================================
- If this update is not being applied to BMC 0.23 or later, please first 
  update to 0.23.
- Copy the update files from this release package to the 
  media(Hard Drive, USB Disk-on-Key, Floppy...) that you wish to perform
  the update from. Files include:  run.bat, 7520JRxx.Hex, FWPIAUpd.exe,
- Execute the run.bat file to begin the firmware update process (if running
  from the Software Update package, select update IMM Firmware option)
- Install the webserver EFS image revision 1.25 by either running upd_efs.bat
  (if running from the Software Update package, select update EFS 
  Webserver option) or by uploading the efs_125.efs file using the web server
  at URL http://xxx.xxx.xxx.xxx/!@efsUpdate. Replace the xxx.xxx.xxx.xxx
  with the IP address used to configure the HTTP web server feature.
  Please use the provided batch file as it contains the necessary -nopc 
  command line switch to FWPIAUPD.exe to successfully update the EFS area.
- Proceed to install the latest FRU/SDR package.

=============================================================================
                           KNOWN ISSUES/WORKAROUNDS
=============================================================================
- This and all future firmware releases will only support the fab -3xx 
  and later Professional and Advanced IMM.
  Fab -2xx and prior modules are no longer supported!

  See the SYSTEM HARDWARE REQUIREMENTS section above for details.

- Please clear the web browser cache if the web server feature was used prior
  to BMC 0.37 as these cached pages will conflict with the pages generated
  with versions after BMC 38 and EFS content rev 1.25.
  The clearing of the web browser cache need only be done once.

=============================================================================
                           FEATURES ADDED With This Release
=============================================================================
BMC 0.52:
- None

BMC 0.51:
- None

BMC 0.50:
  Added new feature - ENABLE AN IPMI COMMAND TO RETRIEVE LAN USER PASSWORDS.	
  Two new IPMI, Intel General Application command, 0xC1 and 0xC2 have been added to 
  support this feature.

=============================================================================
                           ISSUES FIXED With This Release
=============================================================================
BMC 0.52
-DCS 25328 
[X]Press and hold power button with IMM installed. The system will hang. 
-DCS 76355 
Typo Error in Release Notes of BMC51.
-DCS 76359 
Thermal Trip is not Occuring in BMC51.

BMC 0.51
-DCS 24527 
No sel Events for Processor disable
-DCS 21443 
Unable to connect to BMC with wrong password intermittently  
-DCS 24428 
IMM Non-responsive due to memory corruption and/or data-abort.
-DCS 140216 
Unable to logout from Telnet session when four users are logged in
-DCS  44721 
BMC SetGlobalEnables do not map to BMC ClearMsgFlags 
-DCS 140180 
PEF action is not occurring the first time.
-DCS 140216 
TLogon command needs to be removed from help
-DCS  44329  
BMC v.48 does not send SNMP trap with WDT set to STAY ON  

BMC 0.50
-DCS 21376( applicable to all platforms)
Command prompt is getting erased using backspace
-DCS 21891  
DHCP not working with advanced module
-DCS 21526( applicable to all platforms)
Telnet: Displaylog command is working properly without sufficient parameter
-DCS 21516 
Set NMI source" command gives completion code 0x00 for invalid data
-DCS 21324 
Status LED - Status LED indication for Chassis intrusion is wrong
-DCS 21435 
Back status LED and FP status LED are green for thermal trip failure
-DCS 21325 
Status LED - Status LED indication for 'unable to power up condition is wrong
-DCS 21124 
HTTP:  All DIMMs do not show details in web view
-DCS 21569 
no email alerts for sparing completed and SBE - sel entry present
-DCS 20188 
HTTP: Web server becomes inaccessible if the 'Not supported' bit is set once.
-DCS 22840( applicable to all platforms) 
Terminal Mode and Native CLI 'power on' commands are not working
-DCS 21519(applicable to all platforms) 
Console and exit commands are working with other parameter also
-DCS 21379 
Status LED is Solid green even after systems crashes due to memory errors
-DCS 21372 
Unable to connect to BMC with wrong password intermittently
-DCS 21497 
ACPI S4 state is not seen when the system goes to hibernate state

*******************************
End of Current Release Notes
*******************************



===============================================================================
Pedigree of Changes
===============================================================================

BMC 0.48:
-DCS:19924
 IMM does not respond to HTTP requests
-DCS:20194
 BMC TAM WDT alarms being cleared on power off
-DCS:41528
 [LNc] IMM CLI commands do not include ALARM
-DCS:21113
 Enable 1MHz I2C speed on FPGA
-DCS:20049
 Clicking the 'last' button displays incorrect number of records per page.
-DCS:20144
 Incorrect 'Available entries' on the SEL pages
-DCS:20123
 Clicking on 'Previous' button displays incorrect no. of entries from last page.
-DCS:20210
 HTTP: Incorrect SEL percentage displayed on both the SEL pages
-DCS:20664
 CLI overwrites commands when connected on a embedded telnet session 
-DCS:19661
 BMC21/Telnet: Backspace is causing error in telnet
-DCS:42163
 KVM support info in FW not correct
-DCS:20840
 Unable to login as a non-null user using DPCCLI with Jarrell BMC46. 
-DCS:40056
 ARP suspension occurs even when the watchdog is restarted 
-DCS:40056
 ARP suspension occurs even when the watchdog is restarted 
-DCS:40234
 apiKey.tcl:1: Set Channel Security Key not implemented 
-DCS:41691
 Junk characters showed in the screen while the systems is booting 
-DCS:41885
 Telnet/CLI: missing space in interrupt help  
-DCS:41888
 Telnet/CLI: interrupt command not functional
-DCS:40132
 BMC21/Telnet: Prompt setting is not working in telnet 

BMC 0.47:
- DCS: 42200
  Fix for #20373 created another issue (DR#42200) which has been resolved
- DCS: 42362 
  A memory leak in the web server has been resolved
- DCS: 19930 
  Self test errors with IMM Pro; changes that are made for the NCR SOL issue

BMC 0.46:
- DCS: 19438
  Invalid Chassis information and Asset tag  in the 'System Summary' page. 
- DCS: 19850
  Host and domain name updates not successful.
- DCS: 19878
  Gateway IP not getting reflected on the Summary page. 
- DCS: 20076
  False front panel temp lower critical events generated 
- DCS: 20194
  BMC TAM WDT alarms being cleared on power off 
- DCS: 20373
  When user creates a session with USER access, they can run any admin command 
- DCS: 41879
  Telnet/CLI: entering character after valid password "IPMI Session Error" 
- DCS: 41920
  No LAN functionality 
- DCS: 42158
  Watchdog timer test causes FRB timeout failure
- DCS: 76110
  SE7520JR2 FRUSDR 6.6.1-Unexpected sel events for Temp Sensors,
  Power Unit and Terminator
- DCS: 76154
  POST Codes Not Driven by SIO on UUT3

BMC 0.45:
- DCS: 41857
  (X) Power On/Off (warm reset) test hangs at Post C ode 13 or F8  
- DCS: 42201
  SR4850HWx CLI and SOL redirection loses connection frequently  

BMC 0.44:
- DCS: 20125
  KVM : Not able to see video redirection on SE7520JR2 Fab 503 board.

BMC 0.43:
- DCS: 20229
  HTTP: 'Configuration' page fields could be set with 'User' privilege level.  

BMC 0.42:
- DCS: 16837
  FW: User Feature cmd for HTTP/S enables returns incorrect # of data bytes 
- DCS: 20132
  BMC fails self test err #8300
- DCS: 20140
  Multiple email alerts are observed for single SEL entry
- DCS: 20194
  BMC TAM WDT alarms being cleared on power off 
- DCS: 20213
  SCW: There are some errors observed at the end of SCW configuration.
- DCS: 20268
  BMC stops responding very often - SE7520JR2 
- DCS: 20307
  Telnet: Invalid Password leads to BMC reset 

BMC 0.41:
- DCS: 20132
  BMC fails self test err #8300
- DCS: 20140
  Multiple email alerts are observed for single SEL entry
- DCS: 20173
  HTTP: Changing UsrUrl2 adds special characters
- DCS: 41534
  SNMP: SNMPGet of SDR returns wrong values 
- DCS: 41678
  SMTP: Two emails received for the same event

BMC 0.40:
- DCS: 20078
  BMC loses connectivity with KVM Viewer and launching ISM  
- DCS: 20115
  Updating or reading GCM FRU data fails nearly 30% of attempts 

BMC 0.39:
- DCS: 19073
  BMC not responding going across sub-nets for Adv IMM card
- DCS: 19881
  BMC38/Telnet: BMC has become busy(CC is 0xC0), not coming out of this state
- DCS: 19376
  KVM -Rebooting  the system with KVM session active will lock the local  Mouse
- DCS: 19844
  CGI config byte reset to 00
- DCS: 19846
   Web server hangs on clicking ""Clear SEL"" on the page.
- DCS: 19402
  SEL page in EFS content rev 1.6 has errors
- DCS: 19827
  Embedded CLI/SOL functionality is inconsistent and does not display correctly
- DCS: 19690
  Web Server SEL View erratic
- DCS: 19377
  KVM - Mouse control not returned back to Local server.
- DCS: 19891
  SNMP Enable bit resets with power cycle
- DCS: 19454
  SEL page does not display the entries.
- DCS: 19860
  BMC38/Telnet: telnet and HTTP are not working when telnet port is changed
- DCS: 19861
  PS1 Status on the Summary page shows ""Inst"" for ""Installed"".
- DCS: 19880
  BMC38/Telnet: login propmt should not come when all 4 telnet sessions are active
- DCS: 19850
  Host and domain name updates not successful.  
- DCS: 19878
  Network gateway IP not getting reflected on the Summary page
- DCS: 19879
  Host name and Domain name should be clear on the Summary page.  
- DCS: 19438
  Invalid Chassis information and Asset tag  in the "System Summary" page.
- DCS: 19880
  BMC38/Telnet: login propmt should not come when all 4 telnet sessions are active 
- DCS: 19881 
  BMC38/Telnet: BMC has become busy(CC is 0xC0), not coming out of this state  
- DCS: 74756
  FAN 5 and FAN 6 sensor numbers get swapped when IMM installed
- DCS: 19073
  BMC not responding going across sub-nets for Adv IMM card
- DCS: 19881
  BMC38/Telnet: BMC has become busy(CC is 0xC0), not coming out of this state
- DCS: 19846
  Web server hangs on clicking ""Clear SEL"" on the page.
- DCS: 19376
  KVM -Rebooting  the system with KVM session active will lock the local  Mouse
- DCS: 19891
  SNMP Enable bit resets with power cycle
- DCS: 19844
  CGI config byte reset to 00
- DCS: 19850
  Host and domain name updates not successful.
- DCS: 19438
  Invalid Chassis information and Asset tag  in the ""System Summary"" page.
- DCS: 19402
  SEL page in EFS content rev 1.6 has errors
- DCS: 19377
  KVM - Mouse control not returned back to Local server.
- DCS: 19454
  SEL page does not display the entries.
- DCS: 19690
  Web Server SEL View erratic
- DCS: 19723
  [x] Chassis intrussion not being logged in the SEL when opening the side cover
- DCS: 19878
  Gateway IP not getting reflected on the Summary page.
- DCS: 19879
  Host name and Domain name should be clear on the Summary page.
- DCS: 19860
  BMC38/Telnet: telnet and HTTP are not working when telnet port is changed"
- DCS: 19861
  PS1 Status on the Summary page shows ""Inst"" for ""Installed"".
- DCS: 19880
  BMC38/Telnet: login propmt should not come when all 4 telnet sessions are active
- DCS: 19492
  Email Alert is not working for 4 configurations
- DCS: 19585
  LANDesk reports that mux is getting stuck in SYSTEM mode at BIOS POST end
- DCS: 19862
  Alerts not generated for configured filters
- DCS: 19882
  Error while accessing power control and SEL details in EFS web page
- DCS: 19937
  SEL pages not working after few hours of loading BMC 1.39, EFS 1.13
- DCS: 39766
  SDR Clear does not cancel reservation
- DCS: 38098
  SDR EraseTime timestamp Is Not Expected Time Value
- DCS: 74762
  Sometimes BMC will disable event messages from threshold type sensors after A/C off then on
- DCS: 76109
  Sometimes BMC will disable event messages from threshold type sensors after A/C off then on
- DCS: 19654
  Issues with SEL view range in the web server
- DCS: 19840
  Unnecessary characters appear on the left panel in Mozilla.
- DCS: 19882
  Error while accessing power control and SEL details in EFS web page
- DCS: 19907
  SOL: Accepted Character Count field is wrong.
- DCS: 19933
  Issues with automatic refresh of SEL pages and default no. of entries.
- DCS: 19937
  SEL pages not working after few hours of loading BMC 1.39, EFS 1.13
- DCS: 19956
  Issues with ""Next"" button on the ""System Event log/SEL details""  page.
- DCS: 19958
  Issues with ""Previous"" button on the ""System Event log"" page.
- DCS: 19959
  Issues with ""Previous"" button on the ""SEL details"" page.
- DCS: 19969
  embedded web server gives error if cli accessing BMC
- DCS: 19880
  BMC38/Telnet: login propmt should not come when all 4 telnet sessions are active
- DCS: 19881
  BMC38/Telnet: BMC has become busy(CC is 0xC0), not coming out of this state
- DCS: 19937
  SEL pages not working after few hours of loading BMC 1.39, EFS 1.13
- DCS: 19943
  SOL: SOL payloads jam indefinitely. Operation Status = 0x40
- DCS: 20013
  HTTP : After working for around 2 - 2.5 hrs, Found issues with  SEL details page
- DCS: 20038
  DC power cycling is causing network stack to become unavailable.
- DCS: 40062
  Cipher Suite Id 7 & 8 failed to establish a session
- DCS: 40063
  Cipher Suite Id 7 & 8 failed to establish a session
- DCS: 40139
  FSC system booting with 19+ SEL entries
- DCS: 41353
  Telnet 'power -console' fails to show server screen
- DCS: 41588
  SNMP fails to change ports
- DCS: 76000
  FRB2 was not disabling the BSP when the SEL log was full
- DCS: 19912
  System fails to boot with Riggins Base, P06 BIOS & IMM
- DCS: 74773
  SE7520BD2 Fab7 board+ SC5300 base chassis+ IMM (professional version module),
  server system can not power up and have 1-5-4-4 beep warning.
- DCS: 19888
  Fix for data entry format in the IPMI command window.
  It now accepts things like "20 18 1" as well as "20 18 01".
- DCS: 20041
  Enabled the ability to write to the power unit and power supply FRU devices

BMC 0.38:
- DCS: 17571  
  HTTP web server about link causes error 
- DCS: 19402  
  SEL page in EFS content rev 1.6 has errors 
- DCS: 19454
  SEL page does not display the entries
- DCS: 19475
  ctWrong completion code returned for invalid commands in the web page
- DCS: 19558  
  [IMM] Status LED does not return to green from amber
- DCS: 19616
  Fan status LED does not go out after hot swap fan is repaired 
- DCS: 19628
  BMC35/Telnet: Telnet is not working for any other port  
- DCS: 19647
  Incorrect data in the SEL record displayed in the SEL page
- DCS: 19654  
  Issues with SEL view range in the web server
- DCS: 19659
  Wrong "Current power state" shown on the "Power Control" page
- DCS: 19678  
  Embedded web server "Help" link is broken 
- DCS: 19679
  Unexpected character on web server summary page 
- DCS: 19682  
  Dislplay IMM GCM NIC gateway and subnet mask on summary page 
- DCS: 19690
  Web Server SEL View erratic 
- DCS: 19737  
  Unable to telnet for user1 when password is reset 
- DCS: 19801
  Event receiver not set correctly in SATA HSBP after AC cycle 
- DCS: 19824
  Inconsistent mouse and keyboard control on KVM 
- DCS: 19825  
  Power cycling on can cause the BMC to not allow further connections 
- DCS: 19826
  Logging into embedded CLI while KVM ena bled causes BMC reset 
- DCS: 19828  
  Embedded CLI Banner still reads Sahalee BMC Embedded Telnet 
- DCS: 19833  
  Updating NIC configuration during Telnet Session stops LAN interface 
- DCS: 19836  
  Sessions and stress test issues with the web server

BMC 0.37:
- DCS: 19402
  SEL page in EFS content rev 1.6 has errors  
- DCS: 19439
  No data available in the product area of the web page.
- DCS: 19452
  SEL page does not display the entries.  
- DCS: 19497
  Help pages missing in the Embedded web server.  
- DCS: 19534
  EFS Updates failing 
- DCS: 19628
  BMC35/Telnet: Telnet is not working for any other port  
- DCS: 19647
  Incorrect data in the SEL record displayed in the SEL page.  
- DCS: 19654
  Issues with SEL view range in the web server.  
- DCS: 19670
  /!@efsUpdate page can be accessed/executed by any privilege level.  
- DCS: 19677
  "About" box for embedded Web Server copyright date  
- DCS: 19678
  Embedded web server "Help" link is broken  
- DCS: 19679
  Unexpected character on web server summary page  
- DCS: 19680
  Embedded Web Server has ( ) behind DIMMS, etc 
- DCS: 19681
  Remove "product" from web server summary page
- DCS: 19683
  Web Server failure needs to be in Red  
- DCS: 19684
  Web Server summary page needs to show "RPM"  
- DCS: 19690
  Web Server SEL View erratic 
- DCS: 19732
  HTTP does not work for any port other than 80  
- DCS: None
  Sensors that are valid only while DC is on were being scanned
  while DC was off.
- DCS: None
  Separated the PCI HP module set for SR4850HWx as these were conflicting with
  the SE7520AF2 PCI hot plug sensor enumerations.
- DCS: 40239
  Added support for SR4850HWx in the platform mismatch command.

BMC 0.36
- DCS: 39809
  Added new signals in MCH driver
- DCS: None
  Web server enhancements from TME/PME review feedback
- DCS: None
  Moved creation of new command tables to external RAM due to running out
  of internal RAM.

BMC 0.35
- DCS: 19444
  BMC32 Clearlog -state command in Telnet is not behaving as expected  
- DCS: 19468
  BMC32/Telnet: displaylog is not working with "-s" option  
- DCS: 19488
  BMC Prochot monitoring by BMC not reliable 
- DCS: 19482
  Could not connect to the web server in SE7520JR2 BMC 33..
- DCS: None
  Fix for mouse and keyboard getting disabled during system reboot or reset.
- DCS: 19535
  Front Panel reset button not getting locked in Sleep S1state
- DCS: 19493
  BMC33/Telnet: telnet is not working with BMC33

BMC 0.34
- DCS: None
  All advanced IMM features to not work with BMC 0.33
- DCS: 19530
  Get HTTP Configuration Parameters-- Parameter Revision is not 0x11  
- DCS: 19485
  BMC to emulate keyboard / mouse correctly on Win2003 
- DCS: 19494
  Key Board Gets Disabled on Win2000
- DCS: 39476
  Serial over LAN recieved unexpected successful response

BMC 0.33
- DCS: None
  HTTP web server fixes
- DCS: 17503
  Get SNMP Config Params command returns bad completion code
- DCS: 39454
  SMI timeout does not work
- DCS: 39489
  OEM1 bit is un-settable
- DCS: None
  KVM fixes
- DCS: 18215
  Init Agent fails to initialize the sensor thresholds
- DCS: 16670
  HTTP Power Webpage, timestamp needs to be updated
- DCS: 19402
  SEL page in EFS content rev 1.6 has errors

BMC 0.32
- DCS: 17950
  [IMM] Boot Initator info Block seemingly not validated 
- DCS: 19398
  PDB failure status not logged by BMC
- DCS: 15895, 16213, 16597, 16840, 17179, 18805, 19246, and 19321
  Miscellaneous HTTP web server fixes

BMC 0.31
- DCS: 16325
  EMP is not available for 10 seconds after DC ON  
- DCS: 18410
  Communication failure in Terminal mode
- DCS: 19027
  Failed to make direct serial connection (LSM)  
- DCS: 19028
  Failed to establish Serial Modem Connection (LSM)  
- DCS: 19031
  [IMM] SecureModeActive bit is not set by the Secure Mode KB signal.  
- DCS: 19306
  CRERR04 - during console redirection and EMP is enabled
- DCS: 19354
  Enable Telco Alarm Manager feature in SE7520JR2 BMC (IMM)
- DCS: 19363
  BMC 30:SMTP -Parameter Revision is not 0x11 
- DCS: 19369
  SMTP config parm#6, DNS override, inverted 
- DCS: 75975
  [J1-IMM] BMC did not lock the Power and Reset push-buttons when Secure Mode
  signal is asserted.
- DCS: None
  Add support to allow the SE7520JR2 BMC firmware to execute on a SHW4 server

BMC 0.30
- DCS: 15819
  IPMI2.0 commands not implemented correctly.
- DCS: 16415
  KVM - Get Video Status requires video data structure
- DCS: 16634
  FW: Setting an SMTP configuration appears to set multiple configurations
- DCS: 16837
  FW: User Feature cmd for HTTP/S enables returns incorrect # of data bytes
- DCS: 17186
  Get Channel Payload Support responses the same output
- DCS: 17459
  KVM - Set KVM Config. to set in progress results in invalid completion code
- DCS: 17460
  KVM - issuing Set KVM Configuration to disable KVM does not work.
- DCS: 17501
  KVM - Activate Payload not returning all required bytes
- DCS: 17502
  KVM - Video Status incorrectly reported when powered off
- DCS: 17503
  Get SNMP Config Params command returns bad completion code
- DCS: 17538
  FW:  Issues with Set SMTP Config Params command
- DCS: 17540
  FW:  Issues with Set/Get LAN Config Params cmd w/ parameter 0xc4
- DCS: 17773
  KVM - No Video Data Received
- DCS: 17779
  KVM - Video packets still sent after Payload Deactivated
- DCS: 17815
  KVM - Invalid Mouse Type reported
- DCS: 17860
  KVM - BMC Becomes unresponsive to LAN connection
- DCS: 17863
  KVM - Capture Reference Frame has too much data in it
- DCS: 17865
  KVM - System will not boot w/KVM session Active
- DCS: 17949
  LAN: chan 3 MAC Addr not auto-populated
- DCS: 18387
  [IMM] Front Panel LCP is not discovered.
- DCS: 18698
  Status LED does not turn amber when there is a fault on the system
- DCS: 19169
  Restart Cause command is not working as expected
- DCS: 19237
  PCI Hot Plug sensors stuck in init update mode after exit FW-Xfer mode
- DCS: 19239
  [IMM] IERR occured at  AC power cycle test.
- DCS: 19267
  BMC29:Power control fault beep codes are emitted when repeated power cycles are
- DCS: 19299
  LAN Alerts with Alert strings are reported as malformed packets
- DCS: 19321
  EFS format/content not finalized yet
- DCS: 19324
  Mouse / Keyboard Not Initialized when OS booted during  a KVM session
- DCS: 19326
  FPGA Encryption Problematic - After 100 + packets video data length is invalid

BMC 0.29:
- DCS: 19155
  BMC doesn't correctly transition to S1 sleep state
- DCS: 34955
  To implement Memory board Front and rear temperature sensors
- DCS: None
  Better handling of power loss & DC off events.
- DCS: 19139
  Console Redirection Causes Firmware Progress Errors in LD  
- DCS: 38307
  System failed to log AC power failure during boot
- DCS: 19107
  BMC 0.28 Encountered failure while verifying sensor initialization value.  
- DCS: 18875
  Online Firmware Update causes BMC to hang 
- DCS: 19156
  RQ_SyncSMBus command locking wrong bus  
- DCS: 18963
  PS_PWR_GD ISR is not being enabled occasionally
- DCS: 18215
  Removed init agent changes that were causing other problems.
- DCS: 18936
  [IMM] IERR event is always occur right after AC on
- DCS: 19135
  mBMC update with IMM installed fails on SE7520AF2 and SE7520BD2
- DCS: 16483
  BMC and SDR updates fail 
- DCS: 75901
  DC cycling failed with IMM cards installed (Procs go offline)
- DCS: 75907
  Processors being Disabled after an OS Restart
- DCS: 75908
  Problems Powering On after an OS Shutdown
- DCS: 75915
  BMC25 is shutting down immediately after loading and disabling the processors
- DCS: 74593
  BIOS B19~P03 versions cause UUT boot failed after several front panel power
  cycling while IMM card installed.
- DCS: 74618
  IMM fails in SE7520BD2 -601A SCSI

BMC 0.28:
- DCS: 18866 & 18867
  Thermal Trips were calling power control code to power down system. This
  functionality is handled directly by the hardware.
- DCS: None
  Added new module selection for Memory Board
- DCS: None
  Fans would sometimes indicate failure at DC on.
- DCS: 19066
  PCI Hot Plug Sensors do not show up 
- DCS: None
  Power supplies from shutting down due to current spikes caused by fan speed
  changing to quickly.
- DCS: None
  Processors are getting enabled and disabled twice during FRB3 failures.
- DCS: None
  ID LED on would get locked on when button is pushed during power state
  transitions.
- DCS: 18883
  OOB connection not working out of subnet 
- DCS: 19054
  Repeat issuance of CLI power actions causes IMM to stop responding 
- DCS: 19056
  Thermal Trips being seen during DC power cycle testing 
- DCS: 19072
  1-5-4-4- beep code 
- DCS: 19083
  CLI lockup on power commands with BMC A.27 engineering release  
- DCS: 19084
  BMC a.27 causing therm trip and IERR errors on SE7520BD2 and SE7520JR2 

BMC 0.27:
- Only released as incremental developer drops to verify resolutions that are
  in place with the BMC 0.28 release.

BMC 0.26:
- DCS: 19010
  Self test error with LSM Linux Console 
- DCS: 18875
  Online Firmware Update causes BMC to hang 
- DCS: 19056
  Thermal Trips being seen during DC power cycle testing 
- DCS: 19016
  Temporary failure of boot 
- DCS: 18215
  Init Agent fails to initialize the sensor thresholds
- DCS: None
  Added some kick start ramping, but then went to a fixed 50% kick start.
- DCS: 19066
  PCI Hot Plug Sensors do not show up  
- DCS: 38317
  BMC release process not producing repeatable checksums
- DCS: None
  Changed to notify waiting task if multiple loss of arbitration detected,
  regardless of task state.
- DCS: 18963
  PS_PWR_GD ISR is not being enabled occasionally 
- DCS: 19019
  Rapid, succesive activation of the Power button, hangs BMC  
- DCS: 19054
  Repeat  issuance of CLI power actions causes IMM to stop responding 


BMC 0.25:
- DCS: 18963
  PS_PWR_GD ISR is not being enabled occasionally 
- DCS: 18638
  BMC22: OnlineUpdateOpenArea is returning 0x00 as CC when it should not return so
- DCS: None
  Fix for LAN channels not working after an exit firmware transfer mode
- DCS: 18875
  Online Firmware Update causes BMC to hang 

BMC 0.24:
- DCS: None
  Fixed a defect in the VERIFY macro
- DCS: None
  Added support for using a manufacturing test SDR
- DCS: None
  HW team reporting fan circuit FETs being blown due to LM93 PWM outputs being
  driven while DC is off
- DCS: None
  If the private store gets cleared both processors will come up as disabled
  by FRB3 on the next boot
- DCS: 18208
  [IMM] CF9 hard reset does not work 
- DCS: None
  mBMC Driver potential error fix
- DCS: None
  HW folks have the nominal, boost & sleep values set to FCh in the SDRs
  which is wrong.
- DCS: 18217 & 18551
  Implement a bi-color system fault indicator
  (follow-up: counter-act the mBMC's clearing of the LEDs on DC power on)
- DCS: None
  Added defines to nullify printf in release mode
- DCS: 18806
  BMC generates Self Test Error/ Parity Error with LanDesk SOL console 
- DCS: None
  Added support for using a shipping, TDE Adv IMM and TDE Pro IMM SDR.
- DCS: 18217
  The comment describing the mBMC color conversion value assumptions was incorrect
- DCS: None
  Found a memory leak in mactconet.c
- DCS: None
  mBMC Driver reduce number of retries
- DCS: 18461
  HDD LED on front panel is red when IMM is installed 
- DCS: None
  Incorporate the latest FSC spreadsheet data into the LM93 register defaults
- DCS: None
  Added support for handling the IPMI requests Set ACPI Power State
  and Get ACPI Power State through the SMM channel.
- DCS: None
  mBMC Driver parameter tweaking to increase performance 
- DCS: 18866
  [IMM] Thermal trip event is not logged in SEL
- DCS: 18867
  [IMM] IERR event is not logged in SEL
- DCS: 18745
  Fans do not contribute to the overall health of the system 
- DCS: 18883
  OOB connection not working out of subnet 
- DCS: 18243
  2nd CPU fails with frb3 during post 
- DCS: 18802
  BMC failing self test corrupts BIOS information 
- DCS: 18854
  SE7520AF2 BMC 23 - Resolve MAC hangs BMC 
  
BMC 0.23:
- DCS: 16967
  PET Traps were not getting detected
- DCS: 18548
  [IMM] BMC failed BIOS self test after update to  BMC version 21
- DCS: 18612
  BMC does not retain OOB connectivity after installation of ISM on server  
- DCS: 18217
  Front Panel Bi-Color LED behaviour 
- DCS: 18551
  [IMM] Status LED is not changed at  the critical event.  
- DCS: 75827
  [J1] Baseboard Management Controller Failed by Self Test command during POST
  with Sahalee FW 0.21.
- DCS: 18549
  LM93 OEM SDR would cause the BMC to hang 
- DCS: 18595
  FRUSDR version 6.2.1 Update failling with BIOS P01 and BMC 21
- DCS: None
  Added encapsulating PACKED_xxx definitions around some packed structures.
- DCS: None
  Refined the fan control for power ON and Hot swap kick Start;
  Added checks to avoid C, NC Assertions during power ON&Reset;
  Added the de-assertion Actions in the PIA for hot swap fans; Fans boost
  in the particular domain on HS fan removal
  Restored the default Nominal to half by handling the power on and HS kick
  start in the fanctrl.c code
- DCS: None
  New OEM command to restore the non-volatile configuration.
  This command needs to be called by the utility when the platform mismatch
  found during the FW update.
- DCS: None
  SensAvgCreate() would allow illegal input data
- DCS: None
  Baseboards with maximum DIMM capacity were causing systems to reset
  during POST due to the FRB3 timer expiring.
- DCS: None
  mBMC Driver message potential error fix
- DCS: None
  Multiple stack overflow issues
- DCS: None
  This check-in partially addresses clearing out bogus fan failures that are
  persistently stored.
  I have seen issues with moving my IMM between different platform types,