ServerConductor/Blade Server Manager Description and Reference
When a Windows server is being managed, set the BMC according to the documentation provided with CF3e. Only failure monitoring is set using the BMC environment settings utility.
To set failure monitoring on CF3e using the BMC environment settings utility:
The BMC environment settings utility starts.
In this dialog box, set the following information:
Table 3-3 Information to be set in the BMC Environment Settings Utility dialog box
| Item | Default | Setting |
|---|---|---|
| Monitoring errors | Monitor failures (selected) | Set if failures are to be monitored. |
| Monitoring cycle | 5 minutes | Set (in minutes) the interval at which the server is to be monitored for fatal errors, such as a server hangup or OS shutdown. Failures are detected at the specified interval. The permitted value range is from 3 to 60. |
| Processing when a failure occurs | Do nothing | Set the processing to be executed automatically in the event of a server failure. You can set one of the following:
|
| Power-off monitoring | Do not monitor, 10 minutes | If power-off processing fails, use this item to set whether the power-off processing is to be retried within a specified time. To retry the power-off processing, select this check box. The permitted value range is from 10 to 60 minutes. |
| Reboot monitoring | Do not monitor, 10 minutes | If rebooting fails, use this item to set whether rebooting is to be retried within a specified time. To retry rebooting, select this check box. The permitted value range is from 10 to 60 minutes. |