ServerConductor/Blade Server Manager Description and Reference

[Contents][Glossary][Index][Back][Next]

Appendix B.2 System board

Alert ID Level Message Action
0x0561 Failure An abnormal temperature was detected on the CPU in the CPU slot (<d>). Remove dust from the system device's air vent to provide good ventilation. If the same event recurs with good ventilation, contact hardware support or the hardware vendor for the system device.
0x0562 Caution The CPU in the CPU slot (<d>) was degraded. Contact hardware support or the hardware vendor for the system device.
0x0564 Failure An error occurred in the CPU in the CPU slot (<d>). Contact hardware support or hardware vendor for the system device.
0x0569 Warning The temperature of the CPU in the CPU slot (<d>) exceeds the warning value. Remove dust from the system device's air vent to provide good ventilation. If the same event recurs with good ventilation, contact hardware support or the hardware vendor for the system device.
0x0571 Caution Part of the installed memory has been started in a degraded state. Contact hardware support or the hardware vendor for the system device.
0x0572 Information The amount of installed memory is different from the last time. Check if the memory configuration was changed before the system device was started.
0x05B0 Warning An error occurred in the I2C bus. [args] Contact hardware support or the hardware vendor for the system device.
0x0611 Caution A correctable memory error occurred. Contact hardware support or the hardware vendor for the system device.
0x0612 Failure An uncorrectable multi-bit error occurred in memory. Contact hardware support or the hardware vendor for the system device.
0x0613 Failure A processor configuration error was detected. Contact hardware support or the hardware vendor for the system device.
0x0614 Failure A memory configuration error was detected. Contact hardware support or the hardware vendor for the system device.
0x0615 Failure A memory module has been started in a degraded state. Contact hardware support or the hardware vendor for the system device.
0x0616 Warning The memory chip has been changed. No action is required.
0x0617 Failure The BMC detected an error. Contact hardware support or the hardware vendor for the system device.
0x0618 Warning A chipset warning was detected. Contact hardware support or the hardware vendor for the system device.
0x0619 Failure A chipset error was detected. Contact hardware support or the hardware vendor for the system device.
0x061A Failure An error occurred in the PCI hot plug slot. Contact hardware support or the hardware vendor for the system device.
0x061B Warning A warning occurred in the PCI hot plug slot. Contact hardware support or the hardware vendor for the system device.

Legend:
Information: Alerts that report changes in the server status.
Caution: Alerts that indicate the possibility of an error.
Warning: Alerts that indicate the possibility of a failure.
Failure: Alerts that indicate the necessity of prompt action.