Intel(R) Server Boards S5520HC and S5500HCV, and Intel(R) Workstation Board 
S5520SC FRUSDR Release Notes
=============================================================================

INTEL Enterprise Platform & Services Marketing
Intel Corporation
2111 N.E. 25th Avenue, Hillsboro, OR 97124 USA

=============================================================================

DATE:		April 17, 2009

TO:		Intel(R) Server Boards S5520HC, S5500HCV, and Intel(R) Workstation Board
                S5520SC customers

SUBJECT:	Integrated BMC(R) FRU/SDR update package FHC_18 release notes

=============================================================================
                               LEGAL INFORMATION
=============================================================================
Information in this document is provided in connection with Intel products.
No license, express or implied, by estoppel or otherwise, to any intellectual
property rights is granted by this document. Except as provided in Intel's
Terms and Conditions of Sale for such products, Intel assumes no liability
whatsoever, and Intel disclaims any express or implied warranty, relating to
sale and/or use of Intel products including liability or warranties relating
to fitness for a particular purpose, merchantability, or infringement of any
patent, copyright or other intellectual property right. Intel Corporation may
have patents or pending patent applications, trademarks, copyrights, or other
intellectual property rights that relate to the presented subject matter.
The furnishing of documents and other materials and information does not
provide any license, express or implied, by estoppel or otherwise, to any
such patents, trademarks, copyrights, or other intellectual property rights.
Intel products are not intended for use in medical, life saving, or life
sustaining applications. Intel may make changes to specifications and product
descriptions at any time, without notice.

Intel is a registered trademark of Intel Corporation.

*Other names and brands are the property of their respective owners.

Copyright (c) 2009 Intel Corporation.

=============================================================================
                              ABOUT THIS RELEASE
=============================================================================

SDR file version: 0.18
Baseboard FRU file version: 0.05
Master configuration file version: 0.18

SDR data based on system/thermal team SDR spreadsheet rev 1.4


=============================================================================
	     SYSTEM HARDWARE & SOFTWARE REQUIREMENTS/REVISIONS
=============================================================================

- This FRU/SDR package has only been tested on S5520HC / S5500HCV FAB4 (or later)
  and S5520SC Fab3 (or later) baseboards.

- BMC firmware rev 00.35 (or later) MUST be preinstalled prior to installing
  this FRU/SDR package.

- BIOS R0036 or later

=============================================================================
                      IMPORTANT INSTALLATION NOTES
=============================================================================

- None

=============================================================================
			INSTALLATION PROCEDURE
=============================================================================

1. Ensure BMC release 00.35 or later is pre-installed before attempting this
   FRU/SDR update.

2. Copy the FRUSDR18.nsh. FRUSDR.efi. HC_BMC.fru, SC_BMC.fru, HC_BMC.sdr, 
   ipmi.efi, Master.cfg to a USB key, hard disk drive or floppy drive.
   All of the files in this zip archive must reside in the same directory.

3. Now execute the following command to bring up the main FRU/SDR load menu:

	FRUSDR /cfg master.cfg


4. Select the option which is applicable to what you want to do. On a brand
   new baseboard I would highly recommend to run option 3 to program both
   the FRU and SDR. By reprogramming the FRU you will be given the option
   to input data from the keyboard into various chassis, board and product
   areas. Ensure that you select the correct chassis from the chassis
   selection menu otherwise your fan sensors will not be configured
   properly.

5. Once the FRUSDR update is complete, power off the system and apply a AC cycle.

=============================================================================
                           KNOWN ISSUES/WORKAROUNDS
=============================================================================

- None
=============================================================================
                           FEATURES ADDED
=============================================================================
FHC_18:
- Update SDR as per fan profiles rev 1.4.

FHC_17:
- Update SDR as per fan profiles rev 1.2.

FHC_16:
- Update Master.cfg file product name area.

FHC_15:
- Update SDR as per fan profiles rev 1.1.
- Add entering chassis type field in FRU update.

FHC_14:
- Update SDR as per fan profiles rev 1.08.
- Update processor Tcontrol offset.

FHC_13:
- Update SDR as per fan profiles rev 1.06.

FHC_12:
- Update SDR as per fan profiles rev 1.05.
- Separate clamp sub records for the Mem A and Mem B.
- Modify Fan Sensor Scaling SDR Record for OTHER/FCT/FOQM.
- Add QPI sensors in the SDR.
- Fix the different model name of the redundant PS for auto-detection.

FHC_11:
- Update SDR as per fan profiles rev 1.02.
- Modify FRU file version to 0.05

=============================================================================
                           ISSUES FIXED
=============================================================================
FHC_18:
- Correct Entity instance IDs for baseboard temperature sensors.

FHC_17:
- Occasional FRUSDR flash hang at detecting Processor.

FHC_16:
- None.

FHC_15:
- None.

FHC_14:
- None

FHC_13:
- None.

FHC_12:
- None.

FHC_11:
- Info in Base Board (or Module) Information (Type 2) of SMBIOS declare wrong.
- Modified 1.8V sensor Upper Non-Critical warning.
- SDR has incorrect ME address.
- NM Capabilities SDR record has incorrect data.
- Modified the Event Reading Type code for NM Health record.


[END OF RELEASE NOTES]