Peppercon OPMA KIMG3 Release Notes				      2006/02/03
--------------------------------------------------------------------------------

1. Moving the OPMA card from one server system to another

When the OPMA card is taken from one server to another with possibly another 
sensor topology, it is necessary to perform a single restart of the card
once after the whole system (OPMA card and server system) had a successful bootup.
To do so, log in to the OPMA card and choose 'Maintenance', 'Reset device'.
After doing so (and waiting until the card becomes available again) the
card is ready to be used in the new system.

--------------------------------------------------------------------------------
Changes for Firmware version 04.01.00, Build 2800
--------------------------------------------------------------------------------

- fixed activation of fault LED after the server system is powered down
- fixed fans not speeding up when a single fan was faulty
- fixed fan tacho showing too low values
- accept SMTP server for logging without port parameter

--------------------------------------------------------------------------------
Changes for Firmware version 04.01.00, Build 2865
--------------------------------------------------------------------------------

- fixed fault led not becoming active in some situations
- decreased boot time to <30s to meet the OPMA spec
- fix mass storage emulation not getting disabled correctly when discarding
  image or on option change
- fixes in web frontend, remove some unused options