    Intel(R) Server Platform S2600IP/W2600CR FRU/SDR Update Release Notes
=============================================================================

INTEL Enterprise Platform & Services Marketing
Intel Corporation
2111 N.E. 25th Avenue, Hillsboro, OR 97124 USA

=============================================================================

DATE:   Aug 22, 2012

TO:	    Intel(R) Server Platform S2600IP/W2600CR customers

SUBJECT:    IBMC(R) FRU/SDR update package S2600IPCR_FRUSDR_1.09 release notes

=============================================================================
                               LEGAL INFORMATION
=============================================================================
Information in this document is provided in connection with Intel products.
No license, express or implied, by estoppel or otherwise, to any intellectual
property rights is granted by this document. Except as provided in Intel's
Terms and Conditions of Sale for such products, Intel assumes no liability
whatsoever, and Intel disclaims any express or implied warranty, relating to
sale and/or use of Intel products including liability or warranties relating
to fitness for a particular purpose, merchantability, or infringement of any
patent, copyright or other intellectual property right. Intel Corporation may
have patents or pending patent applications, trademarks, copyrights, or other
intellectual property rights that relate to the presented subject matter.
The furnishing of documents and other materials and information does not
provide any license, express or implied, by estoppel or otherwise, to any
such patents, trademarks, copyrights, or other intellectual property rights.
Intel products are not intended for use in medical, life saving, or life
sustaining applications. Intel may make changes to specifications and product
descriptions at any time, without notice.

Intel is a registered trademark of Intel Corporation.

*Other names and brands are the property of their respective owners.

Copyright (c) 2011 - 2012 Intel Corporation.

=============================================================================
                              ABOUT THIS RELEASE
=============================================================================

SDR file version: 1.09
W2600CR FRU file version: 1.00
S2600IP FRU file version: 1.00
Master configuration file version: 1.09
FRUSDR utility version: v11.0_Build14

=============================================================================
        SYSTEM HARDWARE & SOFTWARE REQUIREMENTS/REVISIONS
=============================================================================

- BMC firmware rev 01.04 (or later) MUST be preinstalled prior to installing
  this FRU/SDR package.

- - BIOS 01.02.1002 or later

=============================================================================
                      IMPORTANT INSTALLATION NOTES
=============================================================================

- None

=============================================================================
            INSTALLATION PROCEDURE
=============================================================================


1. Ensure BMC release 01.04 or later is pre-installed before attempting this
   FRU/SDR update.

2. Copy and uncompress all of the files to a USB key,
   
3. Now execute the following command to bring up the main FRU/SDR load menu:

    FRUSDR /cfg master.cfg

4. Follow instructions on the menu. Option 3 is recommended to program both
   the FRU and SDR. By reprogramming the FRU you will be given the option
   to input data from the keyboard into various chassis, board and product
   areas. Ensure that you select the correct chassis from the chassis
   selection menu otherwise your fan sensors will not be configured
   properly.


=============================================================================
                           KNOWN ISSUES/WORKAROUNDS
=============================================================================

=============================================================================
                           FEATURES ADDED
=============================================================================
FRUSDR_1.09:
- I/O Module temperature sensor detection changed.
- Correct ps curr out % upper critical threshold for 1200w/1600w psu.
- Remove power unit redundancy sensor de-assertion event.
- Change the capability of IO/SAS Mod presence sensors to manual-rearm.
- Remove processor disabled event for processor status sensors.
- Change the capability of processor/memory VRD Hot sensors to auto-rearm.
- Modify HDD status sensors As/De event mask as 8300.
- Update Sensor Unavailable Control Value for LAN clamp record to 0.
- Fix BHP PS configuration error.
- Modify M byte to 05h and RExp/BExp byte to F0h for MTT sensors.
- Correct SAS module presence sensor entity instance.
- Update FRUSDR utility to FRUSDR11.0-Build14
- Follow IronPass_CONFIG-FSC.xls(v4.8).

FRUSDR_1.08:
- Change power unit redundancy sensor to manual rearm.
- Change the tag for SDR type 11 related to PSU.

FRUSDR_1.07:
- Add supporting R2000 storage chassis front panel temperature sensor.
- Follow IronPass_CONFIG-FSC.xls(v4.7).
- Update FRUSDR utility to FRUSDR11.0-Build11

FRUSDR_1.06:
- Add SDR type 11 for FRU device locator record.
- Correct SAS module fru entity instance.
- Add IO/SAS module present sensor.
- Rearrange sequence number for HDD status sensors, starting from zero.
- Add no_fan tags for the fan which is not detected.
- Modify IO module clamp temperature.
- Follow IronPass_CONFIG-FSC.xls(v4.6).

FRUSDR_1.05:
- Correct the display to product name.

FRUSDR_1.04:
- R2000IP supports front panel with product name, F2USTOPANEL.
- Change front Panel Temp sensor entity ID from 0x0C to 0x40.
- Add record for PMBus Power Supply Address SDR Format.
- Add tag for 750w ERP PSU for PS fan.
- Remove UCC for ps domain.
- Follow S2600IP_CONFIG-FSC.xls(v4.5).

FRUSDR_1.03:
- Rearrange cpu fan probe sequence.
- Follow S2600IP_CONFIG-FSC.xls(v4.3).
- Follow W2600CR_CONFIG-FSC.xls(v4.0).

FRUSDR_1.02:
- Add Fan Redundancy Map Record for 3rd party chassis.
- Add 1600w PSU detection.
- Support 750w ERP PS previous P/N.
- Detect twice for fan tach detection. 
- Follow S2600IP_CONFIG-FSC.xls(v4.0).
- Follow W2600CR_CONFIG-FSC.xls(v3.9).

FRUSDR_1.01:
- R2000 chassis has no chassis intrusion switch, correct the tag.
- Modify Exit Air Temp sensor As/De event mask as 0000.
- Remove tags for FCT/FCT2.
- Correct IP stepwise curve id 07.
- Follow S2600IP_CONFIG-FSC.xls(v3.9).
- Follow W2600CR_CONFIG-FSC.xls(v3.8).

FRUSDR_1.00:
- Change CFG file, SDR file, FRU file version number to 1.00.
- Remove assertion/deassertion event of Exit Air Temp sensor(0x2E).
- Modify front panel FRU entity id to 0Ch, align the instance to 1h.
- Correct R2000 redundant Chassis ID & FRU LED Mapping.
- Modify 750w ERP PSU P/N to FS750HS1-00.
- Correct the message when 750W ERP PSU is detected.
- Follow S2600IP_CONFIG-FSC.xls(v3.5).
- Follow W2600CR_CONFIG-FSC.xls(v3.5).

=============================================================================
                           ISSUES FIXED
=============================================================================
FRUSDR_1.09:
- System status LED still keep amber blinking when CPU VRD Hot 
  Sensor in Deassert state.
- FRU version update fail.


FRUSDR_1.08:
- None.

FRUSDR_1.07:
- None.

FRUSDR_1.06:
- No "SAS Module Presence" sensor is defined in SDR file.

FRUSDR_1.05:
- None.

FRUSDR_1.04:
- FRUSDR1.03 can't detect R2000IP Redundant Fan sku automatically with FP G28538-201.

FRUSDR_1.03:
- None.

FRUSDR_1.02:
- FRUSDR auto-detection function fail while BMC is in SHIP mode or FCT mode.

FRUSDR_1.01:
- None.

FRUSDR_1.00:
- None.
=============================================================================
                             REFERENCE MATERIAL
=============================================================================
IronPass_CONFIG-FSC Rev4.8 datasheet
CrownPass_CONFIG-FSC Rev4.1 datasheet
[END OF RELEASE NOTES]