        Intel(R) Server Platform S1200RP Integrated BMC Firmware Release Notes       
===============================================================================
Intel Product Collaboration and Systems Division
Intel Corporation
2111 N.E. 25th Avenue, Hillsboro, OR 97124 USA

===============================================================================
DATE:       18 February, 2014

TO:         Intel(R) Server Board S1200RP customers

SUBJECT:    Integrated BMC(R) firmware 01.11.5801 release notes
===============================================================================
                               LEGAL INFORMATION
===============================================================================
Information in this document is provided in connection with Intel products. 
No license, express or implied, by estoppel or otherwise, to any intellectual 
property rights is granted by this document. Except as provided in Intel's 
Terms and Conditions of Sale for such products, Intel assumes no liability 
whatsoever, and Intel disclaims any express or implied warranty, relating to 
sale and/or use of Intel products including liability or warranties relating 
to fitness for a particular purpose, merchantability, or infringement of any 
patent, copyright or other intellectual property right. Intel Corporation may 
have patents or pending patent applications, trademarks, copyrights, or other 
intellectual property rights that relate to the presented subject matter.  
The furnishing of documents and other materials and information does not 
provide any license, express or implied, by estoppel or otherwise, to any 
such patents, trademarks, copyrights, or other intellectual property rights.  
Intel products are not intended for use in medical, life saving, or life 
sustaining applications. Intel may make changes to specifications and product 
descriptions at any time, without notice.

Intel is a registered trademark of Intel Corporation. 

*Other names and brands are the property of their respective owners.

Copyright (c) 2014 Intel Corporation.

A portion of this firmware is open source code.
The OSS source code that the customer is entitled to per OSS license has been
posted on the Intel support website at the following link:

http://downloadcenter.intel.com/Detail_Desc.aspx?agr=Y&DwnldID=21081


This open source code falls under the GPL 2.0 license, please see the license
at the following link:

http://www.opensource.org/licenses/gpl-2.0.php  


===============================================================================
                            ABOUT THIS RELEASE PACKAGE
===============================================================================
Source file: BMC_i_0111r5801.bin
Update script: fwUpdateBMC.nsh

REVISION INFORMATION RETURNED BY GET DEVICE ID COMMAND:
Operational mode:   01.11.5801

UBoot mode:         1.16
Device ID:          0x21
Manufacturer ID:    0x000157

Other version/revision information:
PSU Model          H/W revision      FW Version 
DPS 460KB A          01F               3.09.31

HSBP FW:            1.03
Root/OS/WWW:        9.19
FWPIAUPD Utility:   12.0-Build3

MD5 checksum of BMC_i_0111r5801.bin: b4b96a702b8322e928025727790e78b1

===============================================================================
                         IMPORTANT INSTALLATION NOTES
===============================================================================
The following update process must be followed to ensure a trouble free updating
of your baseboard.  The order is important to minimize any issues for status
checking as different components are initialized.
1.  BMC firmware
2.  BIOS
3.  Manageability Engine (ME) firmware
4.  FRU/SDR package specific to the baseboard.
5.  NIC EEPROM

===============================================================================
                            INSTALLATION PROCEDURE
===============================================================================
1.  Copy the entire contents of the BMC_i_0111r5801.zip archive file to the
    storage medium of your choice. This can be a hard disk, floppy disk
    or USB flash drive.
    All of the files in the zip archive must reside in the same directory.


2.  Boot to EFI and then run the fwUpdateBMC.nsh script file to update the
    Integrated BMC.

    Modification of the update script with your own command line parameters is
    not supported and doing so is at your own risk!


3.  Install latest available FRU/SDR package specific to the platform.

===============================================================================
                     FIRMWARE UPGRADE/DOWNGRADE PROCEDURES
===============================================================================
Upgrade of BMC FW from version 01.09.5544 to later versions will be documented
in the release notes for those versions.  Check for any special instructions
before you perform the update.

Always observe caution when downgrading firmware.

===============================================================================
                        KNOWN ISSUES/WORKAROUNDS/REQUIREMENTS
===============================================================================
- This BMC FW update package is to be used only on PCSD server baseboards and
  does NOT support customer reference boards (CRB) or silicon reference
  platforms (SRP).
  Contact your Intel(R) representative to determine where to download the BMC
  FW for these products.

- The BMC FW image file in this package is to be used only with the provided
  FWPIAUPD update utility.

- Using the FW image file with a SPI flash device programmer will result in a
  non-functional system.

- If you need to run multi-session stress for SOL, setup timeout of each
  session to be longer than 99ms.

===============================================================================
                     FIRMWARE RECOVERY PROCEDURE
===============================================================================
The Recovery process can be initiated by setting the recovery jumper (called 
BMC Force Update Jumper) to the recovery position.

The jumper is normally in the normal/de-asserted position. The system must be
completely powered off (A/C power removed) before the jumper is moved.

After power is re-applied and the firmware update is complete, the system must
be powered off again and the jumper must be returned to the de-asserted
position before normal operation can begin.

A BMC recovery can be accomplished from a USB flash drive. 
1.  Copy the entire contents of the BMC_i_0111r5801.zip archive file to the
    storage USB flash drive.
    All of the files in the zip archive must reside in the same directory.

2.  Remove A/C power from the system and wait 30 seconds.

3.  Move the BMC Force Update Jumper to the recovery position. 
    Details regarding the jumper ID and location can be obtained from the
    Board EPS for that Platform.

4.  Insert the USB flash drive.

5.  Reapply A/C power to the system and power on the system.

6.  The BIOS POST screen will appear displaying the progress press F6 to
    select boot options. At the boot option menu select to boot to the
    EFI SHELL.

7.  Switch to the directory where you stored the update files and then run
    the fwUpdateBMC.nsh script file to update the Integrated BMC.

    Modification of the update script with your own command line parameters is
    not supported and doing so is at your own risk!

8.  Remove A/C power from the system and wait 30 seconds.

9.  Move the BMC Force Update Jumper to the normal position.

10. Reapply A/C power to the system and power on the system.

===============================================================================
                                ISSUES FIXED
===============================================================================
                                01.11.5801:
===============================================================================
- Fixed: Updated Java Signatures files in BMC to support requirement changes of JAVA
===============================================================================
                                01.10.5637
===============================================================================
- Fixed: The BMC may corrupt within 10 DC cycles on the Intel(R) Server board S1200V3RPM.
===============================================================================
                                01.09.5544
===============================================================================
- Fixed: Nothing displayed on Embedded Web Server while logging in it with IPv6
         address (stateless ICMPv6 discovery).
- Fixed: BMC email alerts refused by some servers
- Fixed: Cannot set link-local gateway for BMC Network Management Interface
         using IPv6.
- Fixed: BMC Web Console session not maintained with power cycle.
- Fixed: Add X-Frame-Options to prevent cross-frame scripting.
- Fixed: Browser autocomplete enabled before authentication.
- Fixed: Web Console not defaulting to English when another non-English browser
         is detected.
- Fixed: Update SDR of S1200RP to version 1.06.
- Added: Add ability to disable IPMI over LAN (RMCP/RMCP) from command line or
         web page.
===============================================================================
                                01.08.5091
===============================================================================
- Fixed: No video display in BMC KVM console when SUT wakes up from S1 or S3
         in Win2012.
	
===============================================================================
                                01.07.5021
===============================================================================
- Fixed: After a BMC reset or BMC update a BMC watchdog SEL event is logged and
         system will be in degraded state. Status LED will be green blinking.

===============================================================================
                                01.06.4994
===============================================================================
- Fixed: Update SDR of S1200RP to version 1.05.
- Fixed: BMC update failing after 4 consecutive firmware updates.
         BMC will no longer stay in recovery mode (uboot) after four
         consecutive firmware updates.
- Fixed: Repeated Pwr Unit Redund warning SEL entries when AC power removed
         from either PS1 or PS2.
- Fixed: Corrected Embedded Web Server help text for Serial Over LAN
- Fixed: Updated Embedded Web Console Mouse Mode text
- Fixed: JViewer always shows "Error reading video data" popup and a black
         screen when mouse mode is set to relative and JViewer tries to hide
         the cursor.
- Fixed: The UBoot code detects a bad CRC of the Ram Image when attempting to
         boot after getting a cold reset.

===============================================================================
                                01.05.4775
===============================================================================
-Fixed: Change Intel(R)RMM in EWS into RMM Dedicated Mgmt.
-Fixed: The LCD Screen display is not clear while scrolling error events.
-Fixed: LAN leash lost event is shown during DC cycle testing.
-Fixed: Px DIMM Thrm Mrgn and Px DIMM Thrm Trip not decoding DIMM number
        correctly in the Embedded Web Server SEL text log.
-Fixed: Embedded Web Server SEL text log not decoding BIOS update versions
        correctly.
-Fixed: There are assert events for Mem Err Sensor 0x28 - 'DIMM Thrm Mrgn 1'
        sensor and 'SPS FW Health' sensor after updating ME firmware.

===============================================================================
                                01.04.4674
===============================================================================
-Fixed: Update SDR of S1200RP to version 1.04.
-Fixed: The BMC version information not displaying as expected in Embedded Web
        Server after entering firmware transfer mode..
-Fixed: The host power status show inconsistently betweeen system information
        page and server power control page in Embedded Web Server when system
        is in S1 or S3.
-Fixed: There are assert and deassert events logged for PCH temp sensor 0x22 -
        low critical and low non-critical during DC cycle stress test.
-Fixed: System status LED is incorrect and there is no assert event logged for
        DIMM thermal trip after DIMM thermal trip is triggered.
-Fixed: Multiple KVM socket error and media redirection errors.
-Fixed: Integrated BMC Web Console Keyboard Macro Cltrl+Alt+F1 not working as expected.

===============================================================================
                                01.03.4595
===============================================================================
-Fixed: Update SDR of S1200RP to version 1.03.
-Fixed: RGMII signal integrity test failed on S1200RP.
-Fixed: BMC shared NIC cannot be pinged successfully after BMC shared NIC IP
        address is set in BIOS setup.
-Fixed: The Web Console Event Log page uses IBMC.

===============================================================================
                                01.02.4452
===============================================================================
-Fixed: Update SDR of S1200RP to version 1.02.
-Fixed: DIMM margin resolution isn't right when saving DIMM inventory into
        extend SEL.
-Fixed: There are four BIOS recovery boot entries in the SEL for a recovery
        boot,only two are expected.
-Fixed: When recovery jumper is connected to 1-2 pin(normal mode), system
        always boots from recovery mode after programming a new BIOS offline.
-Fixed: BMC shared NIC cannot be pinged successfully after run VLAN id set/get
        stress test from VLAN id 0 to 4094.
-Fixed: Source of DIMM event does not show in the SEL extended data.

===============================================================================
                                01.01.4412
===============================================================================
-Fixed: Update SDR of S1200RP to version 1.01.
-Fixed: Change resolution of DIMM temp sensor reading.
-Fixed: SUT is reset even when the timer action is "none" after getting a
        Watchdog timeout.
-Fixed: Sensor reading/state for DIMM Thermal Margin 1 is unavailable.
-Fixed: Fail to generate system debug log in Embedded Web Server.
        - Refreshing the page shows the debug log is available
-Fixed: Embedded Web Server Power Policy numbers cannot be set to 255. Per the
        help information 255 should be valid.
-Fixed: There are unnecessary event logged for sensor Voltage BB +5.0V STBY
        (#0xD3) lower non-critical during AC cycle test.
-Fixed: Message shows as "undefined" with ff in Embedded Web Server SEL page
        when SEL is full.
-Fixed: Intel(R) Hybrid Cloud cannot get session ID when use BMC
        username/password with special characters.

===============================================================================
                                01.00.4348
===============================================================================
Initial Production BMC Release
-Fixed: Update SDR of S1200RP to version 1.00.
-Fixed: Count of currently enabled users is changed even after the command to
        "set user access" failed.
-Fixed: Wrong completion code returned after issuing "Get DIMM information"
        IPMI OEM command.
-Fixed: Incorrect response when testing the timer Interrupt-Action Interaction
        when setting pre-interrupt as NMI.
-Fixed: Add user, modify user and delete user function in Embedded Web Server
        causing pop-up error windows.