    Intel(R) Server Platform Freemont Pass FRU/SDR Update Release Notes
=============================================================================

INTEL Enterprise Platform & Services Marketing
Intel Corporation
2111 N.E. 25th Avenue, Hillsboro, OR 97124 USA

=============================================================================

DATE:   Feb 10, 2014

TO:	    Intel(R) Server Platform S1400FP customers

SUBJECT:    Integrate BMC(R) FRU/SDR update package S1400FP_FRUSDR_0105 release notes

=============================================================================
                               LEGAL INFORMATION
=============================================================================
Information in this document is provided in connection with Intel products.
No license, express or implied, by estoppel or otherwise, to any intellectual
property rights is granted by this document. Except as provided in Intel's
Terms and Conditions of Sale for such products, Intel assumes no liability
whatsoever, and Intel disclaims any express or implied warranty, relating to
sale and/or use of Intel products including liability or warranties relating
to fitness for a particular purpose, merchantability, or infringement of any
patent, copyright or other intellectual property right. Intel Corporation may
have patents or pending patent applications, trademarks, copyrights, or other
intellectual property rights that relate to the presented subject matter.
The furnishing of documents and other materials and information does not
provide any license, express or implied, by estoppel or otherwise, to any
such patents, trademarks, copyrights, or other intellectual property rights.
Intel products are not intended for use in medical, life saving, or life
sustaining applications. Intel may make changes to specifications and product
descriptions at any time, without notice.

Intel is a registered trademark of Intel Corporation.

*Other names and brands are the property of their respective owners.

Copyright (c) 2014 Intel Corporation.

=============================================================================
                              ABOUT THIS RELEASE
=============================================================================


SDR file version:                  1.05
Baseboard FRU file version:        0.01
Master configuration file version: 1.05
FRUSDR UTILITY Version:            11.0 Build 20
=============================================================================
        SYSTEM HARDWARE & SOFTWARE REQUIREMENTS/REVISIONS
=============================================================================

- This FRU/SDR package has only been tested on S1400FP baseboards

- BMC firmware rev 01.10 (or later) MUST be preinstalled prior to installing
  this FRU/SDR package

- BIOS R0103 or later

- MB Ver Fab1


=============================================================================
                           KNOWN ISSUES/WORKAROUNDS
=============================================================================

- None

=============================================================================
                           FEATURES ADDED
=============================================================================
S1400FP_FRUSDR_0105:
- Add the ME sensors "PSU1 STATUS" and "PSU2 STATUS".

S1400FP_FRUSDR_0104:
- None.

S1400FP_FRUSDR_0103:
- Update settings for exit air temperature and system air flow.
- Update temperature sensor(#20 #23 #24 #25 #21 #29 #2a #2b #22 #2f) normal minum setting and low critical and low non critical setting.
- Update CPU1 thermal control M value.

S1400FP_FRUSDR_0102:
- Update Global clamp Record sensor 20h threshold to 45.
- Update Global clamp Record sensor CA threshold to 0.
- Update Global clamp Record sensor 5C,5D threshold to 48.
- Add clamp 5C,5D to PSU domain for R2312 chassis SKU.
- Update DIMM air velocity  record for other chassis SKU.
- Update CPU sensor  MSB, LSB to 0080 in Global clamp Record tab.

S1400FP_FRUSDR_101:
- Update temperature point value in Globe Stepwise Records.
- Update LCC temperautre point in Globe Stepwise Records.
- Enable exist air temp and system flow rate sensor.
- Update FP HEX calculate formula.
- Update Domain mask in system airflow formula.
- Update Domain Support in Main sub record.
- Update dimm clamp threshold from -8 to -4.
- Add duplicate record for DIMM as B5.- ADD clamp sensor to domain 1,2.
- Update PSU domain global stepwise head ID.FFMP_04:
- Add Detect UPS Chassis Function in Master.cfg.
- Modify the tag condition for detect Exit Air Temp sensor in Master.cfg.
- Add Chassis intrustion Tag in Master.cfg. 
- Add System Fan 2 Sensor for UPS Chassis.
- Modify sensor Tag for Chassis UPS.
- Modify Sensor name for sensor 'PS1 Fan Tach1'.
- Modify Sensor name for sensor 'PS2 Fan Tach1'.
- Modify sensor name for HDD status.
- Delete DTS Look-up table.
- Add Stepwise Header ID 02.
- Update Stepwise sub-record. 
- Update System airflow formula Record.
- Update Fan sensor domain map record PS domain record.
- Update fan fault value from 100% to FF to enable advancefan failure feature.
- Update Advanced fan failure sub-record.
- Modify auto-rearm bit for sensor Pwr Unit Redund.

FFMP_04:
- Add Detect UPS Chassis Function in Master.cfg.
- Modify the tag condition for detect Exit Air Temp sensor in Master.cfg.
- Add Chassis intrustion Tag in Master.cfg. 
- Add System Fan 2 Sensor for UPS Chassis.
- Modify sensor Tag for Chassis UPS.
- Modify Sensor name for sensor 'PS1 Fan Tach1'.
- Modify Sensor name for sensor 'PS2 Fan Tach1'.
- Modify sensor name for HDD status.
- Delete DTS Look-up table.
- Add Stepwise Header ID 02.
- Update Stepwise sub-record. 
- Update System airflow formula Record.
- Update Fan sensor domain map record PS domain record.
- Update fan fault value from 100% to FF to enable advancefan failure feature.
- Update Advanced fan failure sub-record.
- Modify auto-rearm bit for sensor Pwr Unit Redund.

FFMP_03:
- Initial release

=============================================================================
                           ISSUES FIXED
=============================================================================
S1400FP_FRUSDR_0105:
- None

S1400FP_FRUSDR_0104:
- Update FRUSDR utility to 11 build 20.

FFMP_101:
- The system status LED still remain blinking amber after stop heating Processor 1 Memory VRD Hot 0-1 sensor.

FFMP_04:
- [System Power] PMBUS Sensor reading is fail.
- [FW EVL] Power on SUT with two PSUs,plug out and plug in again a power supply's cable,then plug out another PSU's cable, only a AC lost log generated for it.

FFMP_03:
- Initial release

=============================================================================
                             REFERENCE MATERIAL
=============================================================================

S1400FP_CONFIG-FSC.xls(v2.3)

[END OF RELEASE NOTES]