        Intel(R) Server Platform Integrated BMC Firmware Release Notes       
===============================================================================


INTEL Server Systems 
Intel Corporation
2111 N.E. 25th Avenue, Hillsboro, OR 97124 USA


===============================================================================
DATE:       04 September, 2014



TO:         Intel(R) Server Board S2600xx V3



SUBJECT:    Integrated BMC(R) firmware 01.05.6802 release notes


===============================================================================
                               LEGAL INFORMATION
===============================================================================
Information in this document is provided in connection with Intel products. 
No license, express or implied, by estoppel or otherwise, to any intellectual 
property rights is granted by this document. Except as provided in Intel's 
Terms and Conditions of Sale for such products, Intel assumes no liability 
whatsoever, and Intel disclaims any express or implied warranty, relating to 
sale and/or use of Intel products including liability or warranties relating 
to fitness for a particular purpose, merchantability, or infringement of any 
patent, copyright or other intellectual property right. Intel Corporation may 
have patents or pending patent applications, trademarks, copyrights, or other 
intellectual property rights that relate to the presented subject matter.  
The furnishing of documents and other materials and information does not 
provide any license, express or implied, by estoppel or otherwise, to any 
such patents, trademarks, copyrights, or other intellectual property rights.  
Intel products are not intended for use in medical, life saving, or life 
sustaining applications. Intel may make changes to specifications and product 
descriptions at any time, without notice.


Intel is a registered trademark of Intel Corporation. 


*Other names and brands are the property of their respective owners.


Copyright (c) 2014 Intel Corporation.


A portion of this firmware is open source code.
The OSS source code that the customer is entitled to per OSS license has been
posted on the Intel support website at the following link:

http://downloadcenter.intel.com/Detail_Desc.aspx?agr=Y&DwnldID=21081


This open source code falls under the GPL 2.0 license, please see the license
at the following link:

http://www.opensource.org/licenses/gpl-2.0.php  


===============================================================================
                            ABOUT THIS RELEASE PACKAGE
===============================================================================
Source file: BMC_i_0105r6802.bin
Update script: fwUpdateBMC.nsh

REVISION INFORMATION RETURNED BY GET DEVICE ID COMMAND:
Operational mode:   01.05.6802

UBoot mode:         .
Device ID:          0x21
Manufacturer ID:    0x000157

Other version/revision information:
    PSU Model          H/W revision      FW Version
    1100ADU00201         S4F (S3 HW Rev)  1.01.2D
    1100ADU00201         S3               1.01.2D
    DPS 750XB A          S4               5.**.100 *(See Note 2)
    DPS 750AB-5A         S2               2.**.10  *(See Note 2)
    DPS 1200TB A         00               4.39.77 *(See Note 1)
    DPS 1200TB A         02               6.40.89 *(See Note 1)
    DPS 1200TB A         S3               3.39.77 *(See Note 1)
    PSSF162202A          00               0.09.65
    PSSF162202A          S3               0.09.55 *(See Note 1)

*NOTE 1: Supported but not POR. Will likely be removed in a future release.
*NOTE 2: The middle version number is attached to a particular batch of power supplies and can be
         different for the same firmware revision. Therefore, it cannot be predicted ahead of
		 time what it will be. Validation should ignore this value.

HSBP FW:            01.10 (May be displayed as hex 1.a)
Root:               01.05
OS:                 01.01
WWW:                01.03
uboot:              01.03
FWPIAUPD Utility:   v13.Build5

MD5 checksum of BMC_i_0105r6802.bin: 941ff684f17317edda20efbdf8ea54fd


-------------------------------------------------------------------------------


===============================================================================
                         IMPORTANT INSTALLATION NOTES
===============================================================================
The following update process must be followed to ensure a trouble free updating
of your baseboard.  The order is important to minimize any issues for status
checking as different components are initialized.
1.  BMC firmware
2.  BIOS/Manageability Engine (ME) firmware (as directed in BIOS Release Notes)
3.  FRU/SDR package specific to the baseboard.
4.  NIC EEPROM

===============================================================================
                            INSTALLATION PROCEDURE
===============================================================================
- NOTE: This release contains a change in the low level boot area that can only
  be updated using a device programmer. This low level boot code change is to fix
  an issue with not being able to properly re-establish an SOL session after a BMC
  reset due to a FW update.
  The firmware can be updated normally using the usual update methods with the only
  effect being that you will not get that one particular fix for SOL.
  
  If upgrading from BMC FW 0.19 or older or you need the SOL fix, you need to update
  using a device programmer. If you already have version 0.20 or newer and you do not need
  the SOL fix, use the following steps. Note that when updating using a device programmer,
  you will lose all FRU data and will need to reprogram the default FRU data again using
  the FRUSDR package.
  
1.  Copy the entire contents of the BMC_i_0105r6802.zip archive file to the
    storage medium of your choice. This can be a hard disk, floppy disk
    or USB flash drive.
    All of the files in the zip archive must reside in the same directory.


2.  Boot to EFI and then run the fwUpdateBMC.nsh script file to update the
    Integrated BMC.

    Modification of the update script or using fwpiaupd.efi with your own
    command line parameters is not supported and doing so is at your own risk!


3.  Install latest available FRU/SDR package specific to the platform.

===============================================================================
                     FIRMWARE RECOVERY PROCEDURE
===============================================================================
The Recovery process can be initiated by setting the recovery jumper (called 
BMC Force Update Jumper) to the recovery position.

The jumper is normally in the normal/de-asserted position. The system must be
completely powered off (A/C power removed) before the jumper is moved.

After power is re-applied and the firmware update is complete, the system must
be powered off again and the jumper must be returned to the de-asserted
position before normal operation can begin.

A BMC recovery can be accomplished from a USB flash drive. 
1.  Copy the entire contents of the BMC_i_0105r6802.zip archive file to the
    storage USB flash drive.
    All of the files in the zip archive must reside in the same directory.

2.  Remove A/C power from the system and wait 30 seconds.

3.  Move the BMC Force Update Jumper to the recovery position. 
    Details regarding the jumper ID and location can be obtained from the
    Board EPS for that Platform.

4.  Insert the USB flash drive.

5.  Reapply A/C power to the system and power on the system.

6.  The BIOS POST screen will appear displaying the progress press F6 to
    select boot options. At the boot option menu select to boot to the
    EFI SHELL.

7.  Switch to the directory where you stored the update files and then run
    the fwUpdateBMC.nsh script file to update the Integrated BMC.

    Modification of the update script with your own command line parameters is
    not supported and doing so is at your own risk!

8.  Remove A/C power from the system and wait 30 seconds.

9.  Move the BMC Force Update Jumper to the normal position.

10. Reapply A/C power to the system and power on the system.

NOTE: Performing this recovery procedure resets all network and user settings to defaults.
      The FRUSDR will also need to be reloaded after a recovery (SDR update).

===============================================================================
                     FIRMWARE UPGRADE/DOWNGRADE PROCEDURES
===============================================================================
Upgrade of BMC FW from version BMC_i_0104r6789 to later versions will be documented
in the release notes for those versions.

Reverting to a lower version of firmware may have unexpected side effects,
including but not limited to user settings reset to defaults, and will always
result in the loss of functionality which was present in the higher version
but was not implemented in the lower version.
We do not guarantee that any downgrade will operate without side-effects.

Always observe caution when downgrading firmware.

===============================================================================
                        KNOWN ISSUES/WORKAROUNDS/REQUIREMENTS
===============================================================================
- This BMC FW update package is to be used only on PCSD server baseboards and
  does NOT support customer reference boards (CRB) or silicon reference
  platforms (SRP).
  Contact your Intel Representivate to determine where to download the BMC FW
  for these products.

- The BMC FW image file in this package is to be used only with the provided
  FWPIAUPD update utility.
  Using the FW image file with a SPI flash device programmer will result in a
  non-functional system.
  
===============================================================================
                                ISSUES FIXED
===============================================================================
01.05.6802 (Production Release)
===============================================================================

-EPSD100241497: BMC cannot be contacted until AC power cycle after restoring defaults
-EPSD100243953: EWS server health page sensor reading show " Not Available" for " PS Fan Fail" sensor.
===============================================================================
01.04.6789
===============================================================================

-EPSD100243920: [X] BMC flash process breaks SOL session until system is rebooted
-EPSD100244023: During AC power cycling test, found the BMC becomes unstable.  (BMC reset)
-EPSD100241497: BMC cannot be contacted until AC power cycle after restoring defaults
===============================================================================
01.02.6745
===============================================================================

-N/A: Update S2600KP built-in SDR's to version 1.00
-EPSD100242984: Intel RAID Cards: SEL flooded with events when doing a RAID rebuild or Drive Replacement
===============================================================================
01.01.6653
===============================================================================

-EPSD100243323: Status LED still is green blinking after auto configuration handles the fan redundancy sensor correctly.
-EPSD100243460-EPSD100243463:SyscfgV13.16:"syscfg.efi /bbo" get boot order failed once Win2k12R2UEFI OS connected and boot mode set to "UEFI" 
-N/A: 1600W Power Supply Firmware changed to 9.65.
-EPSD100243179: SEL show  "Warning event: BB 2.62V VPP reports it crossed the lower non-critica" during warm cycle.
-EPSD100243180: SEL show like "Warning event: BB 1.2V PXDDR xx reports it crossed the lower non-critical" during warm cycle.
-EPSD100243284: SEL show "Warning event: BB 1.05V VCC IO reports it crossed the lower non-critical." during warm cycle.
-EPSD100242714: FAN speed can't be set to 100%.
-N/A: OpenSSL changed to version 1.0.1i

01.00.6572

-EPSD100242648: Reports LAN Leash has been lost asserted, then de-asserted on chassis reset
-EPSD100242994: some items translation in Chinses browser don't align with that in English browser.
-EPSD100026690: Unexpected PSU event logs if only install one PSU in KDK and power on the SUT
-EPSD100242992: voltage fault sensor 0xD1 status check fail.
-EPSD100241819: HSBP Temp event is logged in DC cycle stress


===============================================================================
                             REFERENCE MATERIAL
===============================================================================
Common (integrated) BMC Firmware EAS
(integrated) BMC Firmware Common Core EPS