Intel(R) Server Board S2600WT product family, Intel(R) Server System R1000WT 
	product family and Intel(R) Server System R2000WT product family 
	Firmware Update Package for Intel(R) Deployment Assistant, Intel(R) One
	Boot Flash Update Utility, The embedded EFI Shell, Windows* Preboot 
	Execution Environment 
================================================================================
Intel Enterprise Platform & Services Division - Marketing
Intel Corporation
2111 N.E. 25th Avenue, Hillsboro, OR 97124 USA
================================================================================
DATE    : 	Jul 28, 2015
TO      : 	Intel(R) Server Board S2600WT product family
		Intel(R) Server System R1000WT product family
		Intel(R) Server System R2000WT product family
                customers
SUBJECT : Release Notes for System Firmware Update Package 
================================================================================
                              ABOUT THIS RELEASE
================================================================================
BIOS:     	01.01.0009
ME:        	03.00.07.168
BMC:     	01.28.8586
FRUSDR:		1.08
================================================================================
                           Support Platforms and Dependency
================================================================================
Processors supported: 
Intel(R) Xeon processor E5-2600 v3 series

Microcode update versions:
Intel(R) Xeon processor E5-2600 V3 series C1 stepping: 0x00000023 CPUID = 0x306f2

Production boards:
  Product		Fab Version	      
  S2600WT		Fab3 (PBA# -35x) or above    

The following update process must be followed to ensure a trouble free update.
1.	BMC firmware
2.	BIOS
3.	Manageability Engine (ME) firmware
4.	FRUSDR



================================================================================
                  System Firmware Update Package Usage instructions                   
================================================================================

To update from Intel(R) Deployment Assistant (IDA)

Download the Intel(R) Deployment Assistant from 
https://downloadcenter.intel.com/download/24412/Intel-Deployment-Assistant-iso-image
To use the IDA CD to update the system firmware:
- Boot server with IDA CD
- Select "Get System Updates" 
- Choose one of the three options 

  . From http://www.intel.com/support/
    Automatically downloads the latest Firmware Update Package from Intel 
    Requires Internet connection
    Enter your local IP address and proxy configuration
    Click "Next" to start the download and update process

  . From my network
    Download the latest Firmware Update Package from 
	http://downloadcenter.intel.com/ and copy it to a Windows* shared folder
    Enter your local IP address, the Windows* file server name, and a
    Windows user name and password
    Select the firmware package in pop-up window
    Click "Next" to start the update process

  . From USB flash drive or Hard Disk
    Download the latest Firmware Update Package from 
	http://downloadcenter.intel.com/ and copy it to a USB flash drive, then
	insert the USB flash drive into the server USB port
    Click "Browse"
    Select the firmware package in pop-up window
    Click "Next" to start the update process
    
  Note: 1) The Firmware Update Package is in the ZIP file format. Do not unzip 
        before copying to a Windows* shared folder or USB flash drive.
	2) The IDA will always update backup bios with this SFUP package even if
	the IDA backup bios check box is not selected.

To update from Windows* and Linux* or operating systems using the Intel(R) One 
	Boot Flash Update Utility (OFU)

Intel(R) One boot Flash Update utility can be downloaded from 
	http://downloadcenter.intel.com/ and is part of the "BIOS, Firmware 
	Update & Configuration Utilities" for Windows* and Linux*. Please refer 
	to Intel OFU user guide about the details of installation and usage of
	OFU.

Use OFU to update system firmware by the following steps:
- Install OFU on Windows* or Linux* system
- Download the latest firmware update package from 
	http://downloadcenter.intel.com/
- Unzip package to a folder
- Run the following command in Windows* command line/Linux* terminal window:
  <OFU install folder name>:\flashupdt -u  <package folder name>\flashupdt.cfg
                       
To update from Windows* Preboot Execution Environment (WinPE)

The System Firmware Update Package can be inserted to Windows* PE customized 
	image for creating a bootable Windows* PE CD. User is able to update 
	system firmware from customized WinPE CD by the following steps:
- Boot server with customized WinPE CD
- Run script "WinPE_x64_Update.bat" or "WinPE_x86_Update.bat" 
  (name may be varied depends on your own customization)
  
Note:

1. The Intel(R) OFU utility is case sensitive. Therefore, when you transfer the 
	Firmware Update Package using USB flash drive from a Microsoft Windows* 
	system to a Linux environment, you must first extract under the Linux* 
	environment. Otherwise, you will need to mount the USB flash drive 
	manually with 'vfat' option under Linux to avoid conversion from upper 
	case to lower case and vice versa.

2. To make Intel(R) OFU utility run properly under x86 or x64 OS, you have to 
	read OFU release notes on known issues for OFU installation.

3. In this SFUP package, Intel only provide batch file "WinPE_x86_Update.bat"
for WinPE2.0 32 bit solution "WinPE_x64_Update.bat" for WinPE2.1/3.0 64 bit 
solution as an example. Please refer to white paper "White Paper-Intel Server 
Utilities Procedure for WinPE.pdf" for details on building your own customized 
WinPE CD.

4. Windows PE 2.0 - built from Windows Vista SP1 32bit or EM64T
5. Windows PE 2.1 - built from Windows Vista SP1 or Windows Server 2008, EM64T
6. Windows PE 3.1 - built from Windows Server 2008R2, EM64T
7. Microsoft IPMI driver is loaded by default from WinPE CD, if you want to use
	Intel IPMI driver instead of MS IPMI driver for firmware update, you can
	uninstall Microsoft IPMI driver by:
                Devicesetup.exe -v remove *IPI0001
                Note: IPI0001 is the device ID for Microsoft IPMI driver.
8. If to update backup BIOS region or NVRAM, you need to customize the OFU
	update 	scripts (eg.flashupdt.cfg) and add "UpdateBackupBios" or 
	"UpdateNvram" parameter.
 
================================================================================
			IMPORTANT NOTICE
================================================================================
1. The BIOS R01.01.0002 auto scripts will force to update both normal and backup 
   BIOS region since security revision was updated, Once user upgrade BIOS to 
   R01.01.0002, it will prevent BIOS downgrade to previous version that with low
   security revision, user can use BIOS recovery mode for BIOS downgrade
2. The BIOS R01.01.0003 included security fix and security revision upgrade, 
   refer to item #1.
3. If doing online BIOS update to R01.01.0003, user must use the auto scripts 
   enabled in the release package which will force update BIOS NVRAM and backup
   region. 
4. BIOS R01.01.0004 requires update of NVRAM and backup region.
5. BIOS R01.01.0009 will enable UEFI Secure Boot and include below limitations:
    - Please read "BIOS UEFI SECURE BOOT IMPACT AND MITIGATION METHOD" section in this
	  BIOS release notes 
	- All customer settings saved in BIOS NVRAM will be lost after new BIOS upgrade. 
    - BIOS downgrade is not allowed if user has enabled BIOS secure boot. All customer 
	  setting will be lost also if downgrade to previous BIOS release.
    - Backup BIOS region is also required to be updated to prevent recovery failure 
	  please use release package to update BIOS.  
    - There is downgrade hang risk if you don't follow above rules. 
	- Further BIOS release will not suffer from these side effects as the NVRAM region 
	  is formatted as authenticated variable storage 
	

================================================================================  
     BIOS UEFI SECURE BOOT IMPACT AND MITIGATION METHOD 
=================================================================================   
1. Customer Setting Loss Issue and Mitigation Method
    When user upgrades BIOS with secure boot feature, the NVRAM will be automatically 
  formatted as authenticated variable physical storage. However, all previous customer 
  settings storage in NVRAM will be lost even if user does not enable UEFI secure boot 
  feature. 
    Users can take the follow recipe to save and restore their settings based on 
  the actual NVRAM usage if they wish to upgrade or downgrade between BIOS with or 
  without secure boot feature. 
    Supposing customer requires to save & restore their specific NVRAM named 'var':
  Steps:
  1. Prepare FAT partition USB key (or HDD).
  2. Boot to EFI shell.
  3. Check the file system mapping (e.g. fs0:) of the USB key with 'map -r' command.  
  4. Use 'dmpstore var -s fs0:\var.bin' to save the variable to the physical file.
  5. Perform BIOS update and reboot system.
  6. Boot to EFI shell.
  7. Use 'dmpstore var -l fs0:\var.bin' to restore the variable.
  8. Reboot the system if the customer setting requires reboot to take effect.

Notes:
  1. Immediate reboot after BIOS update is mandatory. Or the restore operation will 
     not take effect.
  2. Customers can repeat step 4 and step 7 for several times if they need to save & restore 
     multiple NVRAM variables.
  3. Most of BIOS customer settings by SysCfg can also be restored in this way. Customers 
     can follow previous step1~8 by substituting 'Setup' for 'var' in the sample. 
  4. For BIOS downgrade case, step7 cannot be used to restore authenticate variables 
     (e.g. PK, KEK, DB, DBX) to non-authenticated NVRAM storage

2. Recovery Mode Failure
   There is known bug that it cannot POST successfully with authenticated NVRAM storage.
   This will cause platform recovery failure and permanent deny of service (PDOS) if the 
   primary BIOS region gets corrupted for some reason. It is required to update backup BIOS 
   region when upgrade BIOS capsule with secure boot feature. 
Notes: 
  For downgrade case, user is not required to update backup BIOS region as new 
  BIOS with secure boot feature can handle NVRAM with old storage format: 
  it will format it to new authenticated variable storage automatically.  
  However, care must be taken when downgrading BIOS in recovery mode: After flashing 
  BIOS without secure boot feature, user should restore recovery HW jumper immediately 
  before platform reset.If platforms reset occurs before restoring recovery HW jumper, 
  the backup BIOS will once again format NVRAM to new storage format, which will cause 
  newly flashed BIOS (without secure boot feature) POST failure after user restores 
  recovery HW jumper.


================================================================================
			FEATURES ADDED/REMOVED
================================================================================

================================================================================

================================================================================
				R01.01.0003  (Production Release)
================================================================================


================================================================================
                               R01.01.0004 (D633)
================================================================================
EPSD100026893	i350(Powerville) IOM OpROM doesn't load during post
EPSD100244275	Cannot enable TXT and receive BIOS POST Code 0xA100
EPSD100244186	Power Restore Delay Value minimum not long enough for BMC boot 
                time
EPSD100244174   Security vulnerability on SMI GetVariable interface was captured
                by SeCOE
================================================================================
				R01.01.0004
================================================================================
EPSD100026935	The Default Value Of SOL And Console Redirection
EPSD100244254	Pre-Release 40G IOmodule fails the link margin test with concurrent
                traffic on slot2 IOM riser+carrier.
EPSD100244186	Power Restore Delay Value minimum not long enough for BMC boot time
EPSD100026931	Show error message when disabled boot devices
EPSD100244439	[X] Customized riser card on riser slot 2 can't detect InfiniBand* 
                card
EPSD100244388	"Resume AC power loss" status in the file which is save by cmd 
                "syscfg /s A.ini /f /b" wont be changed once change its status with
   				syscfg.
EPSD100243547	Pre-release 40G IOmodule fails the link margin test with concurrent 
                traffic on slot2 IOM riser+carrier.
EPSD100244367	Add 19.3 NIC package EFI driver and FCOE ROM 
EPSD100244376	Syscfg /bldfs does not work same as BIOS F9 function to load default
                BIOS setting "Resume AC power loss" and "Shutdown Policy"
EPSD100244377	Syscfg /bldfs does not work same as BIOS F9 function to load default
                BIOS setting "Resume AC power loss"
EPSD100244374	Syscfg /bldfs does not work same as BIOS F9 function to load default
                BIOS setting "Resume AC power loss" and "Shutdown Policy"
EPSD100244379	Syscfg /bldfs does not work same as BIOS F9 function to load default
                BIOS setting "Resume AC power loss"
EPSD100244371	"Shutdown policy" and "Resume AC power loss" status in the file which
                is save by cmd "syscfg /s A.ini /f /b" wont be changed  once change 
				their status with syscfg.
EPSD100244380	"Shutdown policy" and "Resume AC power loss" status in the file which
                is save by cmd "syscfg /s A.ini /f /b" wont be changed  once change 
				their status with syscfg.
EPSD100244387	"Shutdown policy" and "Resume AC power loss" status in the file which
                is save by cmd "syscfg /s A.ini /f /b" wont be changed  once change
				its status with syscfg.
EPSD100244394	uEFI iSCSI Boot attempts can be saved without filling in the target name

================================================================================
				R01.01.0005
================================================================================
EPSD100244208   SEL intermittently reports therm trip

================================================================================
				R01.01.0006
================================================================================
EPSD100245152 SMBIOS problem cause the latest IDA7.17.RC6 boot failure with the
              12G SAS RS3LC bridge
EPSD100243827 The boot devices will increase if system reboot from RHEL7 aware 
              UEFI and then the system will hang at high proportion
EPSD100026915 The Hdds couldn't be found on the RHEL7.0 when storage card 81605Z 
              inserted in the test riser4_slot4_PCIex16.
EPSD100244480 The boot devices will increase if system reboot from RHEL7 aware UEFI
              and then the system will hang at high proportion
EPSD100243758 Display L2/L3 cache error detected on the RAID controller during post .
EPSD100026786 SUT can't boot to RHEL 6.5 x64 when enable "VT for Directed I/O" in
              BIOS setting.

================================================================================
				R01.01.0007
================================================================================
EPSD100245440  	LAN1 link down when doing DC cycle test with ITAS 

================================================================================
			Issues fixed in ME 03.00.07.168 release
================================================================================   
Permanent Node Busy completion code received when trying to ColdReset ME after setting new value of SlopeComp and Offset coefficients.
After increasing scanning period of DC Power sensor, min correction time for policies in secondary power domain (DC power) will not be updated.
SpsInfox86 crashes when executed with 64-bit addressing enabled.
Node Manager cannot maintain power limit after PSU power loss in Redundant PSU Configuration.
When "PIA Platform PSU Efficiency" sensor is disabled in xml Node Manager uses incorrect power reading for power limiting.
The sensor 0x18 SEL for HW protection policy correction time exceeded.
Get NM Parameter cmd (FAh) responds with incorrect readings when the sensor scanning is disabled.
Potential race condition in NM component handling SMART/CLST functionality.

===============================================================================
                         Issues fixed in BMC 01.28.7601
===============================================================================
01.28.8586
-EPSD100248398: Spelling error in SEL log.
-EPSD100248427:  After SUT power off, there is "Front panel temp sensor has failed and may 
not be providing a valid reading - assert" logged for BMC FW health sensor
-EPSD100248399: Change Bad Passwordk Threshold parameter string in EWS to be same with spec.
-EPSD100248480: Chassis intrusion is always enabled on MTM2 exit.


01.25.8108
-N/A: Update CWP FCT/Shipping SDR to version 1.09.
-N/A: Update KNP/TLP FCT/Shipping SDR to version 1.09.
-N/A: Update WCP FCT/Shipping SDR to version 1.04.
-N/A: GetHomeAgent emits an irritating number of messages when only one CPU is installed.

01.24.8063
-EPSD100246940: Slow response when get RMM4 lite present via IPMI command.
-EPSD100247083: fan sensor reading is always 0 with BMC 1.18 on CWP Kontron SKU.
-EPSD100246496: Configuration Error SELOG issue.
-EPSD100027622: DIMM Thermal margin event is triggered if installed QFSS or  QGSL CPU with A1 and C1 DIMM populated.
-EPSD100247637: Launching BMC KVM with Java Version 6 generates error message.
-N/A: Change LSI3008 VR Temperature Sensor Number to 0x93.
-N/A: Show NVMe Bridge Board Presence. The Bug will happen if there is PCIE Slot 4 on SMBUS2.

01.23.8033
-EPSD100247768: [SLV]Post hang up with PCISSD P3600 or P3700 for 24HDD. TLP not show correct status on NVMe Bridge Board.

01.22.7928
-EPSD100245947: Copyrigth time is not correct in EWS and KVM legal notices.
-EPSD100246765: WCP - SEL events for SAS Mod Presence take place when the system is powered off and on.
-EPSD100246529: [X] All sensor readings are 'N/A' in EWS -> Server Health -> Power Statistics.
-EPSD100027156: [MIC-FW]There is no event logged for sensor "Voltage Fault".
-EPSD100245020: DFT violation 1578, BMC don't provide a programmatic method to control LCP displays.
-EPSD100246021: [x] After removing "AutoCfg Status" from SDR file, the sensor will still be asserted.
-EPSD100246992: [X] "AutoCfg Status" sensor asserted when the server board is installed in a 3rd party chassis.
-EPSD100247180: [X] "AutoCfg Status" sensor asserted when the server board is installed in a 3rd party chassis.
-N/A: Update CWP FCT/Shipping SDR to version 1.08.
-N/A: Update 750W DC power to 3.3.25.
-N/A: Updated SMBIOS fields to version 2.8.0.
 
01.20.7736
-none: Fix the issue that BMC cannot update NVMe Bridge Board FRU online.

01.19.7639
-none: Support 24HDD HSBP on KennedyPass and TaylorPass
-none: Implement a new OEM command for BIOS to discover NVMe Bridge Board.

================================================================================
                    FEATURES ADDED  FRUSDR 1.08
================================================================================    
S2600WT_108:
- Cut in FRUSDR.efi and ipmi.efi utility 13.1 build 6 to support secure boot.

S2600WT_107:
- Add session audit SDR for Bad User PWD.

=============================================================================
                            LEGAL INFORMATION
=============================================================================
Information in this document is provided in connection with Intel products. 
No license, express or implied, by estoppel or otherwise, to any intellectual 
property rights is granted by this document. Except as provided in Intel's 
Terms and Conditions of Sale for such products, Intel assumes no liability 
whatsoever, and Intel disclaims any express or implied warranty, relating to 
sale and/or use of Intel products including liability or warranties relating 
to fitness for a particular purpose, merchantability, or infringement of any 
patent, copyright or other intellectual property right. Intel Corporation may 
have patents or pending patent applications, trademarks, copyrights, or other 
intellectual property rights that relate to the presented subject matter.  
The furnishing of documents and other materials and information does not 
provide any license, express or implied, by estoppel or otherwise, to any 
such patents, trademarks, copyrights, or other intellectual property rights.  
Intel products are not intended for use in medical, life saving, or life 
sustaining applications. Intel may make changes to specifications and product 
descriptions at any time, without notice.

Intel is a registered trademark of Intel Corporation. 
*Other names and brands are the property of their respective owners.
Copyright (c) 2015 Intel Corporation.

A portion of this firmware is open source code, which falls under the
GPL 2.0 license.  

[END OF RELEASE NOTES]