This table describes the return codes that are shown and recorded in the log file when running Configurator CLI commands.
| # | Description |
|---|---|
| 0 | The requested operation completed successfully |
| 1 | Intel AMT is already configured on this system |
| 2 | Intel AMT is already unconfigured on this system |
| 3 | This system does not have Intel AMT (or it is disabled in the Intel MEBX, or the correct drivers are not installed or enabled) |
| 4 | This system supports Intel® Small Business Advantage (Intel® SBA) and cannot be configured by Intel SCS components. Intel SBA systems were specifically designed for small businesses, and can only be configured using the software included with Intel SBA. |
| 6 | The RCS failed to process the request |
| 7 | The Intel AMT device does not have a PSK (prerequisite for the requested operation) |
| 8 | Invalid command parameter |
| 9 | The system is not in Intel AMT mode (check the manageability setting in the Intel MEBX) |
| 10 | The manageability mode has been changed to “AMT”. You must reboot the system to complete this operation. |
| 11 | Failed to change to Intel AMT mode (check the manageability setting in the Intel MEBX) |
| 12 | An internal error has occurred in Intel AMT |
| 16 | Invalid format used in the new Intel MEBX password parameter (refer to the documentation) |
| 17 | Invalid format used in the current Intel MEBX password parameter (refer to the documentation) |
| 18 | Cannot write the USB configuration data to file (possible reasons- the specified path does not exist; no write permissions; not enough free space). |
| 19 | Failed to create the USB configuration file (invalid IP) |
| 20 | Failed to create the USB configuration file (invalid power package) |
| 21 | An internal error occurred when creating the USB configuration file |
| 22 | An internal exception occurred when processing the request |
| 25 | The system is already in Intel AMT mode |
| 26 | The UsingDHCP parameter was supplied, but DHCP is not active on the host operating system |
| 27 | Access denied. Make sure that the user has administrator permissions on the local host or in the Intel AMT device. |
| 30 | This Intel AMT device does not support host-based configuration |
| 31 | This Intel AMT device is in a state that does not support the ConfigAMT command |
| 32 | The requested operation completed, but with warnings |
| 33 | Failed to configure this Intel AMT device |
| 34 | Failed to do the requested operation. The flash wear-out protection mechanism limits consecutive operations in a certain time period. Try the operation again later. |
| 35 | A certificate request was sent to the Certification Authority but the created certificate was put into "Pending Requests" waiting for approval. Intel SCS does not support pending requests. |
| 36 | Failed to request the certificate |
| 37 | Failed to parse the XML file (possible reasons- the file does not exist or access to it is denied; the file contains incorrect parameters; incorrect or missing encryption password/parameter) |
| 38 | Error with XML file (possible reasons- the file does not exist or access to it is denied; the file contains incorrect parameters; incorrect or missing encryption password/parameter; invalid data) |
| 39 | The Intel AMT device is in a state that does not support disabling the Client Control mode |
| 40 | This system was already unconfigured. The system was successfully put in the “Pre Provisioned” state and the Intel AMT interfaces are now closed. |
| 41 | The certificate cannot be retrieved because access to the Certification Authority is denied |
| 42 | Failed to write to the file. A possible reason is insufficient permissions in the selected folder. |
| 43 | Failed to read from the given file. A possible reason is insufficient permissions in the selected folder. |
| 44 | Memory Allocation Error |
| 45 | Failed to unconfigure this Intel AMT device or Intel AMT unconfiguration failed |
| 46 | Settings defined in the dedicated network settings XML file are not compatible with the network settings defined in the configuration profile |
| 49 | Failed to do the requested maintenance tasks on this Intel AMT device |
| 50 | The Intel AMT device is in a state that does not support the Maintenance command |
| 51 | TLS cannot be configured because cryptography is disabled on this system |
| 54 | The Intel AMT device cannot be set with the host FQDN and a dedicated FQDN |
| 55 | The Intel AMT device cannot be set with the host IP and a dedicated IP |
| 56 | An FQDN is mandatory for configuration (supply the FQDN in the NetworkSettings tag of the profile) |
| 57 | Setting a static IP to the Intel AMT device from the host dynamic IP is not permitted |
| 58 | When defining a static address, the IP and subnet mask parameters are mandatory |
| 59 | Failed to find the host IP address and subnet mask to set in the Intel AMT device (possible reasons - the network card is disabled; the network connection is disabled; the network cable is unplugged) |
| 60 | Dedicated FQDN is not permitted |
| 61 | An invalid IP address was supplied in the parameter |
| 62 | Cannot configure an AD object or certificates for the Intel AMT device without a valid FQDN |
| 65 | Administrator credentials must be supplied in the XML or CLI to configure the Intel AMT device |
| 66 | Failed to reissue certificates because the certificate data is missing in the profile |
| 67 | Failed to renew the AD password because the AD data is missing in the profile |
| 68 | Invalid parameter was found |
| 70 | Failed to connect to the Intel AMT device (possible reasons: the system does not have Intel(R) AMT or is not responding; user access to it is denied) |
| 71 | The buffer maximum size supplied in the function is too small |
| 73 | Failed to put the system in the “Pre Provisioned” state (you can try to unconfigure the system using the Intel MEBX “Full Unprovision” option) |
| 74 | Failed to complete the Setup operation on this Intel AMT device |
| 75 | Failed to complete remote configuration of this Intel AMT device |
| 76 | The file supplied in the FileToRun parameter returned an error when it was run |
| 77 | Missing mandatory parameter |
| 78 | Failed to put the Intel AMT device in the “In Provision” state. The Start Configuration operation failed. Examine the Intel MEBX settings to make sure remote configuration is enabled, or a TLS PSK pair is defined. |
| 79 | Failed to connect to the Intel Management Engine Interface PTHI client |
| 80 | Failed to complete the System Discovery |
| 81 | Failed to run the file supplied in the FileToRun parameter |
| 82 | The FileToRun parameter is not permitted for configuration methods using a Remote Configuration Server |
| 83 | The Intel Management Engine Interface driver is not installed or cannot be accessed |
| 84 | Invalid data in the profile |
| 85 | Failed to move the Intel AMT device to Admin Control mode |
| 86 | Failed to get the FQDN |
| 87 | Failed to verify the signature of the file supplied in the FileToRun parameter. To cancel this verification, run the command using the LowSecurity global option. |
| 88 | The requested operation was aborted because required file access failed |
| 89 | The file supplied in the FileToRun parameter is not located in a trusted location. To cancel this prerequisite, run the command using the LowSecurity global option. |
| 90 | Failed to get the Digest admin password to put in the Intel AMT device (calculated by the RCS using the Digest Master Password) |
| 91 | Failed to get the Digest admin password that is configured in the Intel AMT device |
| 92 | Failed to send the Hello Message to the RCS |
| 93 | Failed to submit the certificate request to the Certification Authority |
| 94 | Failed to get the certificate |
| 95 | Failed to generate a TLS-PSK Pair |
| 96 | Failed to generate the PKCS10 request |
| 97 | Failed to get the FQDN of the Intel AMT device |
| 98 | Failed to get the IP address of the Intel AMT device |
| 99 | Failed to get the UUID of the Intel AMT device |
| 100 | Failed to get the FQDN and the IP address of the Intel AMT device |
| 101 | The remote configuration operation completed, but with warnings |
| 102 | Failed to retrieve the PID from this Intel AMT device |
| 103 | The requested functionality is not supported on this operating system |
| 104 | Failed to renew the Digest admin password in the Intel AMT device because the administrator password is missing in the profile |
| 105 | Failed to read data from the registry. A possible reason is that the registry value does not exist or access to it is denied. |
| 106 | Failed to verify the hash of the file supplied in the FileToRun parameter against the Hash supplied in the FileHash parameter |
| 107 | The Notify RCS operation failed |
| 108 | This Intel AMT system already exists in the database |
| 109 | Failed to connect to the RCS |
| 110 | Failed to verify the file signature chain. Either connect the computer to the Internet, or manually download and install the root certificate update package from the Microsoft update catalog. |