       Intel(R) Xeon(R) Processor-Based Server BIOS Development
================================================================================

 INTEL Product Collaboration and Systems Division
Intel Corporation
2111 N.E. 25th Avenue, Hillsboro, OR 97124 USA

================================================================================

DATE    : May 06, 2015
TO      : Intel(R) Xeon(R) Processor-Based Server Platform customers
SUBJECT : Manageability Engine Release notes for version SPS_03.00.07.024

================================================================================
                           LEGAL INFORMATION
================================================================================

Information in this document is provided in connection with Intel Products
and for the purpose of supporting Intel developed server boards and systems.
No license, express or implied, by estoppel or otherwise, to any intellectual 
property rights is granted by this document. Except as provided in Intel's 
Terms and Conditions of Sale for such products, Intel assumes no liability 
whatsoever, and Intel disclaims any express or implied warranty, relating to 
sale and/or use of Intel products including liability or warranties relating 
to fitness for a particular purpose, merchantability, or infringement of any 
patent, copyright or other intellectual property right. Intel Corporation 
may have patents or pending patent applications, trademarks, copyrights, or
other intellectual property rights that relate to the presented subject matter.
The furnishing of documents and other materials and information does not 
provide any license, express or implied, by estoppel or otherwise, to any such
patents, trademarks, copyrights, or other intellectual property rights.  
Intel products are not intended for use in medical, life saving, or life 
sustaining applications. Intel may make changes to specifications and product
descriptions at any time, without notice.

Intel is a registered trademark of Intel Corporation. 

*Other names and brands are the property of their respective owners.

Copyright (C) 2015 Intel Corporation.

================================================================================
                              ABOUT THIS RELEASE
================================================================================
Build Stamp : ME Firmware             --> 03.00.07.024
              ME Recovery Boot Loader --> 03.00.07.024
Build Date  : May 06, 2015

================================================================================
                           Supported Platforms
================================================================================
	S1200RP LC/SE/RM/RO
================================================================================
                        ME RECOVERY INSTRUCTIONS
================================================================================
The Recovery process can be initiated by setting the recovery jumper (called ME
FRC UPDT Jumper)

The following steps demonstrate this recovery process:
   1.  Power OFF the system.
   2.  Switch the ME FRC UPDT jumper. Details regarding the jumper ID and
       location can be obtained from the Board EPS for that Platform.
   4.  Power ON the system.
   5.  Enter Setup and verify Error manager displays 83A0 error code
   6.  Boot to EfiShell and update ME if necessary
   7.  AC OFF the system, and revert the ME FRC UPDT jumper position to
       "normal operation".
   8.  Power ON the system.
   9.  Enter setup and verify Error Manager does not display 83A0 error code

Note 1 : ME will continuously monitor recovery jumper. Whenever ME FRC UPDT is
         asserted ME will immediately switch to recovery mode.  AC Power cycle
         is required after de-asserting ME FRC UPDT jumper for ME to function
         normally.
Note 2 : When MC FRC UPDT jumper is asserted with AC OFF, ME will restore to
         factory default settings.


================================================================================
				ME FW Capsule INSTALLATION NOTES
================================================================================
WARNING:  It is very important to follow these instructions as they are written.
Failure to update using the proper procedure may cause damage to your system.

!!!!! AC failure during update may cause damage to your system and be unrecoverable !!!!!


Please follow the below procedure to update ME using UEFI iFlash32 12.0 Build 4
   1.  Boot the system to EFI Shell
   2.  Download ME release package
   3.  Unzip the ME release package to HD or USB Flash Drive
   3.  Map the respective storage device in system with the command
           Shell> map -r
   4.  Change the Shell to mapped device file system
           Example: Shell> fs0: (or fs1:)
   5.  Run the IFlash32 utility on the prompt.
       Use MEComplete_xx_xx_xx_xxx.cap file when the whole ME Image update is required.
           fs0:\> IFlash32 [File Name] /u /ni
   6.  Reboot system after the update is completed.
================================================================================
      KNOWN ISSUES in 03.00.07.024 release
================================================================================
ME removes data from status registers on PAGE 0
Setting MGPIO[4] or Disabled[15] as recovery jumper does not work
No response from FW for Read/Write mphy settings command after EOP
HRT statistics are not cleared after ME reset
Non-aggressive total domain power policy also limits power in memory domain
after S0->(S3,S4)->S0 transition

================================================================================
      Issues fixed in 03.00.07.024 release
================================================================================
- Fixed: Platform does not go to S3/S4 state in recovery mode
- Fixed: Wrong value returned from Get Max Allowed Logical Processors command after
         S0->(S4,S3)->S0 transition

================================================================================
			Issues fixed in 03.00.07.018 release
================================================================================
- Fixed: Wrong value returned from Get Max Allowed CPU P-states/T-states while limiting
		using Total Power Budget

================================================================================
			Issues fixed in 03.00.07.013 release
================================================================================
- Fixed: SPS FW does not make the override for the capability register using BDW ES parts and
		this results to have ECC, Trifurcation and Dual Dimm per channel OFF.

================================================================================
			Issues fixed in 03.00.07.012 release
================================================================================
- Fixed: Steps to reproduce: 0. Burn new image NMon (SKU NM) AlwaysOn 1. Boot to OS 2.
		Execute power flows in random way Expected results: Platform should properly
		execute power flow. Actual results: After 59 iteration ME send E3 00 command

================================================================================
			Issues fixed in 03.00.05.128 release
================================================================================
- Fixed: Bit Reserved16 in PCH Strap 15 is set incorrectly. This change in Flash 
       Descriptor was introduced in previous release and reverted in this one.

=============================================================================
			Issues fixed in 03.00.05.110 release
================================================================================
- Fixed: Factory Presets and AIM, OCS and OCP MFS files are not readable using MESDC
       or Diagnostic Service.
================================================================================
================================================================================
			Issues fixed in 03.00.05.068 release
================================================================================
- Fixed: "Firmware Update In Progress bit does not set in FW Status register
         during online update.
- Fixed: ME-BIOS Interface major and minor version swapped on EFI and DOS.
- Fixed: The Mode Manager does not support reading power from HSC, when the 
         LM25066i chip is used.
- Fixed: After ME reset (Cold Reset command, or any host reset in S0/S1 Only power
         mode except host warm reset) ME returns incorrect version and CRC of mPhy
         settings (0). This causes the BIOS to perform (unnecessary) mPhy settings 
         update in ME, which gets rejected with 0x101E error code while it should
         be accepted.
- Fixed: Sporadically on some platforms ME may be reset during host booting due
         to internal exception.
- Fixed: Read mPhy settings HECI message returns ICC_STATUS_FAILURE (0x0001)
         in ICC Status field.
- Fixed: PCH register SECRT98 (SATA Electrical Control Register T98) has improper
         value due to incorrect mPhy settings value in ME. As a workaround the BIOS 
         may force update of these settings during boot.
================================================================================
			Issues fixed in 03.00.04.209 release
================================================================================
- Fixed: Disabling spectrum spread with ICC_SET_SPREAD_SPECTRUM message over HECI
         causes the BIOS to hang.
- Fixed: When PSU Status sensors are disabled and one of the PSUs gets disconnected
         from AC, ME resets due to exception, causing SPS FW Health sensor 0x17 event
         to be stored in the BMC SEL.
- Fixed: When Factory Defaults are restored using IPMI command, there is incorrect
         SPS FW Health sensor 0x17 event sent to the BMC SEL.
- Fixed: Sometimes Dynamic Core Allocation temporarily parks cores in unexpected
- Fixed: Sometimes aggressive power policy in Domain Total is not able to limit 
         power in specified correction time.

================================================================================
			Issues fixed in 03.00.04.164 release
================================================================================
- Fixed: Sometimes Dynamic Core Allocation temporarily parks cores in unexpected
         cases. 
- Fixed: Sometimes aggressive power policy in Domain Total is not able to limit
         power in specified correction time.
- Fixed: MESDC "ME-BIOS communication" flow test fail even when "BIOS ICC Set 
         Clock Enable message" test is unchecked. 
- Fixed: Several lines are doubled in LPTAB_NM.XML.
- Fixed: Some MESDC SUSRam entry displayed as "Entry Format is unknown". 

================================================================================
			Issues fixed in 03.00.04.162 release
================================================================================
- Fixed: System will shutdown when running Windows* reboot After executing
         "power button override" flow platform enters Sx state and stops responding.
         ME configured for operating in S0-only. 
- Fixed: IPMI: Wrong value of "reading/state unavailable" bit for Get Sensor Reading
         Command - CPU Thermal Status Sensor.
- Fixed: ME FW became unresponsive when it put into Recovery mode and no CPU
         installed on the platform.
- Fixed: CPU is not being fused properly during first boot after SPI flashing when
         board and FW are configured for operating in S0-only mode. 
- Fixed: It is not possible to disable Hotham functionality using BIOS HECI message. 
- Fixed: Memory and CPU power statistics are always equal 0W. 
- Fixed: Shutdown action could be interrupted by cold reset when volatile policies 
         are used. 
- Fixed: During limiting the power isn't kept in the range of 2.5%
         (power limit is changed every 2 sec) Invalid statistic values with
         throttling policy in domain 0x00. 
- Fixed: MolleteBend-D: GetSensorReading returns not stable values as data field. 
- Fixed: PeciProxy component hangs after sending CPU PCIConfigRd/Wr command 16 times.
- Fixed: Dynamic Core Allocation stopped working after a few minutes If cable is
         removed from backup PSU, power readings are not zeroed. 
- Fixed: Memory throttling statistics are != 0 when NM does not limit power
        (just after fw burn).
- Fixed: Wrong throttling statistic calculation in mode 03 and 0x13. 
- Fixed: Impossible to create non aggressive police in memory domain. 
- Fixed: [NM Event] Lack of Operational Capabilities Change (ME Reset and Platform reset). 
- Fixed: No response for HMRFPO_GETSTATUS command after EOP in Operational Mode. 
- Fixed: FW health event data=0xA0040B during DC power cycling test. 
- Fixed: Continuous: After reset from DOS ME goes to M3, HOST goes to Sx. 
- Fixed: Events from Node Manager Operational Capabilities Change Sensor are 
         generated when disabled. 
- Fixed: Settings provided by IPMI command "Set Max Allowed CPU P-state/T-state"
         are ignored after S0->Sx->S0 transition. 
- Fixed: De-assertion instead of assertion event is generated for Total domain, when
         power or temperature readings are lost. 
- Fixed: "Host Communication Error" is being sent only when the host OS returns to 
         operating state.
- Fixed: ME FW sends too many health events when "factory presets" partition is corrupted.
         Only one event should be sent. 
- Fixed: The access for PIA_SDR data flash area is not restored after defined flash wear
         out protection period. This access is locked permanently. 

================================================================================
			Issues fixed in 03.00.03.082 release
================================================================================
- Fixed: The system may not boot when it gets shutdown by "power button override"
- Fixed: The recovery mode (RCV) jumper does not function correctly. When the 
         platform boots with RCV on and its gets switched off, the Host does to
         Sx power state. 
- Fixed: BIOS: Console redirection to RS-232 doesn't work 
- Fixed: ME does not send command "ME changed power state" after receiving 
        "Host Reset With Power Cycle" or while restarting from OS. 

================================================================================
			Issues fixed in 03.00.03.078 release
================================================================================
- Fixed: When MFS is corrupted, ME hangs for more than 60s and doesn't send the 
         appropriate health event 
- Fixed: FW does not wake up in operational mode when recovery image is corrupted. 
- Fixed: ME not operational after cold reset when VSCC table is empty. 
- Fixed: "OEM ME Power State Change" IPMI frame will be sent twice during Host 
         Transition from Sx to S0 with the "Flash Override Security Strap" jumper
         asserted. 
- Fixed: Some times (randomly, after several dozen continuously performed power cycles),
         after power button override or host reset with power cycle ME stops responding 
         to IPMI commands. Still responses to diagnostic commands. 
- Fixed: Some times when PSU optimization functionality is enabled power under load
         may not reach it maximum value after Node Manager stops power capping. 
- Fixed: Unstable power limiting when OEM Power readings are used for delivering 
         platform power consumption information. 
- Fixed: Wrong ME FW Status register value when Security strap override jumper asserted.
         Operating Mode field is not set to 4 "RECOVER_JMPR - Security Strap Override
         asserted, 
- Fixed: sometimes during P-state switching power limiting mechanism stops working. 
- Fixed: Time After Host Reset Policy triggers later than expected. 
- Fixed: Hotham getSignalsBlockState command makes ME FW unresponsive. 
- Fixed: Hotham getCrystalsCheckStatus command reports test status as failed in case
         host has transited from G3 to any other state. 
- Fixed: The HSC input voltage has a resolution of 1 volt. It should be 0.1 volt. 
- Fixed: Missing Readings Policy triggers earlier than expected. 
- Fixed: "NM enabled" bit in Node Manager Firmware Status (NMFS) in HECI-2 HFS Register
        is never been set properly due to fact that Node Manager using invalid AUX 
        registers for PTState estimation.

================================================================================
			Issues fixed in 03.00.02.203 release
================================================================================
- Fixed: [OS Install] All OS Installation tests with RSTe mode are blocked Sensor
         SSB Temp always in upper critical state Sensor P1 MTT state display 
         incorrectly in EWS
- Fixed: Failed to read some ME sensors with command "Get sensor reading"
- Fixed: RSTe OPROM cannot enabled with R006 on Fab 103 board.
- Fixed: Clock Run Enable for FLEXn option is not accessible. 
- Fixed: Lack of "DMI Clock Divider"and "DMI Spread Generator Enable" options. 
Some fields in PCH Straps section should set differently for lpt platform. 