    Intel(R) Server Board S2600GZ/GL, Intel(R) Server System R1000GZ/GL and Intel(R) Server 
    System R2000GZ/GL FRU/SDR Update Release Notes
=============================================================================

INTEL Product Collaboration and Systems Division
Intel Corporation
2111 N.E. 25th Avenue, Hillsboro, OR 97124 USA

=============================================================================

DATE:       February 10, 2017

TO:         Intel(R) Server Board S2600GZ/GL,  Intel(R) Server System R1000GZ/GL and Intel(R) 
              Server System R2000GZ/GL customers

SUBJECT:    FRU/SDR update package release notes

=============================================================================
                               LEGAL INFORMATION
=============================================================================
Information in this document is provided in connection with Intel Products
and for the purpose of supporting Intel developed server boards and systems.
No license, express or implied, by estoppel or otherwise, to any intellectual 
property rights is granted by this document. Except as provided in Intel's 
Terms and Conditions of Sale for such products, Intel assumes no liability 
whatsoever, and Intel disclaims any express or implied warranty, relating to 
sale and/or use of Intel products including liability or warranties relating 
to fitness for a particular purpose, merchantability, or infringement of any 
patent, copyright or other intellectual property right. Intel Corporation 
may have patents or pending patent applications, trademarks, copyrights, or
other intellectual property rights that relate to the presented subject matter.
The furnishing of documents and other materials and information does not 
provide any license, express or implied, by estoppel or otherwise, to any such
patents, trademarks, copyrights, or other intellectual property rights.  
Intel products are not intended for use in medical, life saving, or life 
sustaining applications. Intel may make changes to specifications and product
descriptions at any time, without notice.

Intel is a registered trademark of Intel Corporation.

*Other names and brands are the property of their respective owners.

Copyright (C) 2017 Intel Corporation.


=============================================================================
                        ABOUT THIS RELEASE PACKAGE
=============================================================================

SDR file version:                   1.14
Baseboard FRU file version:         0.01
Master configuration file version:  114
FRUSDR loader version:			    14.0 Build 8
FRU/SDR release notes:			    1.00 rev 1.4

SDR data based on system/thermal team SDR spreadsheet rev 7.1

=============================================================================
	     SYSTEM HARDWARE & SOFTWARE REQUIREMENTS/REVISIONS
=============================================================================

- Intel(R) Server Board S2600GZ/GL FAB 3 or higher

- Intel(R) Xeon(R) processor E5-2600 product family B0 stepping or higher. 

- Integrated BMC firmware 01.00.2612 (or later) MUST be preinstalled prior to installing
  this FRU/SDR package.

- BIOS 01.01.1002 or later

- Front Panel and Hot-swap backplane FRU data must be available for chassis
  auto-detection to succeed.

=============================================================================
                      IMPORTANT INSTALLATION NOTES
=============================================================================

- None

=============================================================================
			INSTALLATION PROCEDURE
=============================================================================

1. Ensure BMC FW release 01.14.1421 or later and BIOS 01.01.1002 or later are
   pre-installed before attempting this FRU/SDR update.

2. Copy all of the files to a USB flash drive, hard disk drive or floppy 
	drive formatted to use the FAT32 file system

3. Then execute the following script to bring up the main FRU/SDR load menu:

     UpdateFRUSDR.nsh

4. The package should auto-detect the chassis. If it does not, it will print
   an error message indicating why auto-detection failed and then present
   the standard chassis selection menu.


=============================================================================
                           KNOWN ISSUES/WORKAROUNDS
=============================================================================

- None

=============================================================================
                           ISSUES FIXED
=============================================================================
FRUSDR 1.14
- Power supply unable to identify model when flash FRUSDR via OFU

FRUSDR 1.13
- None

FRUSDR 1.12
- Added FRU file for S2600GL and Updated Master.cfg

FRUSDR 1.11:
- Updated frusdr.efi utility version to 11.0 Build 20

FRUSDR 1.10:
- Non-critical threshold values for BB +1.05Vccp P1 and BB +1.05Vccp P2 w/ E2403 and E2407

FRUSDR 1.09:
- Updated vBat volatage sensor scaling factor

FRUSDR 1.08:
- Updated fan profiles based on 7.1 spreadsheet
- Changed vBat scaling factor and thresholds

FRUSDR 1.07:
- R2000GZ/GL system hot-swappable fan feature issue
- R2000GZ/GL system fans hot-swap feature failure

FRUSDR 1.06:
- Revert change to always install Riser Power Good sensors.
- Change to recognize DC Input Power Supplies.

FRUSDR 1.05:
- Scaling incorrect for the MTT sensors.
- Removed Riser Temperature Sensors
- Always install Riser Voltage sensor SDRs

FRUSDR 1.04:
- BMC Web UI can't detect 2U 8x2.5 Dual Port HSBP(G51828-101) Temperature.
- Cannot detect temperature sensor on -250 IO Module
- Power Supply Redundancy sensor should be Manual Rearm.
- Updated to FSC Spreadsheet version 6.6

FRUSDR 1.03:
- Fixed: Storage Front Panel Temperature sensor reads higher than ambient
- Changed strings output to screen during SDR update to more accurately describe the system.
- Fixed: BMC disk drive numbering scheme does not match LSI tools (RWC2 and webBIOS) 
  numbering scheme and marketings documentation.
- Fixed: Issue with detecting the 2U PCIe Riser for Auxillary cooling.

FRUSDR 1.02:
- Changed strings output to screen during SDR update to more accurately describe the system.
- BMC disk drive numbering scheme does not match LSI tools (RWC2 and webBIOS) numbering 
  scheme and marketings documentation.
- Fixed an issue with detecting the 2U PCIe Riser for Auxillary cooling.

FRUSDR 1.01:
- Updated to 6.2 of the Thermal FSC Spreadsheet
- FRUSDR update is not recognizing valid FRU on 1U 4 x 3.5" HSBP
- SPS FW Health sensor (ME) SDR had incorrect Sensor Type and Event/Reading Type codes
- Fixed a typo in the DIMM Air Velocity OEM record for R1000 chassis

FRUSDR 1.00:
- Updated to 6.0 of the Thermal FSC Spreadsheet
- R1000 chassis now has redundant fans
- Fixed issue of not prompting for chassis if HSBP FRU invalid
- When the Onboard NIC 1 is disabled in BIOS, the system fans boost and they should not
- BMC Web Console is showing sensor Agg Therm Mgn 7 status =deasserted, Health = 
  unknown for 2U Systems

=============================================================================
                           FEATURES ADDED
=============================================================================
FRUSDR 1.14:
- None

FRUSDR 1.13:
- Add "PSU1 Status" and "PSU2 Status" SDR for ME SmaRT&CLST SEL support

FRUSDR 1.12:
- None

FRUSDR 1.11:
- None

FRUSDR 1.10:
- None

FRUSDR 1.09:
- None

FRUSDR 1.08:
- None

FRUSDR 1.07:
- Added FSC SDR records to support Intel MIC cards

FRUSDR 1.06:
- None

FRUSDR 1.05:
- None

FRUSDR 1.04:
- None

FRUSDR 1.03:
- None

FRUSDR 1.02:
- None

FRUSDR 1.01:
- None

FRUSDR 1.00:
- Some restructuring to detect chassis type in less time

=============================================================================