   Intel(R) Server Platform S1200BTL/S1200BTLRM FRU/SDR Update Release Notes
=============================================================================

Intel(R) Server Boards and Systems
Intel(R) Corporation
2111 N.E. 25th Avenue, Hillsboro, OR 97124 USA

=============================================================================

DATE:   Sep 06, 2012

TO:	    Intel(R) Server Platform S1200BTL/S1200BTLRM customers

SUBJECT:    Integrated BMC FRU/SDR update package 1.16 release notes

=============================================================================
                               LEGAL INFORMATION
=============================================================================
Information in this document is provided in connection with Intel products.
No license, express or implied, by estoppel or otherwise, to any intellectual
property rights is granted by this document. Except as provided in Intel's
Terms and Conditions of Sale for such products, Intel assumes no liability
whatsoever, and Intel disclaims any express or implied warranty, relating to
sale and/or use of Intel products including liability or warranties relating
to fitness for a particular purpose, merchantability, or infringement of any
patent, copyright or other intellectual property right. Intel Corporation may
have patents or pending patent applications, trademarks, copyrights, or other
intellectual property rights that relate to the presented subject matter.
The furnishing of documents and other materials and information does not
provide any license, express or implied, by estoppel or otherwise, to any
such patents, trademarks, copyrights, or other intellectual property rights.
Intel products are not intended for use in medical, life saving, or life
sustaining applications. Intel may make changes to specifications and product
descriptions at any time, without notice.

Intel is a registered trademark of Intel Corporation.

*Other names and brands are the property of their respective owners.

Copyright (c) 2013 Intel Corporation.

=============================================================================
                              ABOUT THIS RELEASE
=============================================================================

SDR file version: 1.16
Baseboard BTP_BMC FRU file version: 0.03
Baseboard BTP_BMC_RM FRU file version: 0.01
Master configuration file version: 1.16

=============================================================================
        SYSTEM HARDWARE & SOFTWARE REQUIREMENTS/REVISIONS
=============================================================================

- This FRU/SDR package has only been tested on S1200BTL FAB3 and S1200BTLRM 
FAB1 baseboards.

- BMC firmware rev 1.15 (or later) MUST be preinstalled prior to installing
  this FRU/SDR package.

- BIOS R0040 or later

- HSBP_PSOC_FW_0.9 (or later) MUST be preinstalled prior to installing
  this FRU/SDR package.

=============================================================================
                      IMPORTANT INSTALLATION NOTES
=============================================================================

- None

=============================================================================
            INSTALLATION PROCEDURE
=============================================================================

1. Ensure BMC release 1.15 or later is pre-installed before attempting this
   FRU/SDR update.

2. Copy all of the files related to FRUSDR1.16 archive to a USB key,
   hard disk drive or floppy drive.
   All of the files archive must reside in the same directory.

3. Boot to EFI and then run the following command to display the
   contents of the baseboard FRU device:

    FRUSDR /d FRU

   If device is empty(which is the case for all new FAB1 baseboards) or corrupted, then
   execute the following command to program the empty FRU device:

   For S1200BTL:
        FRUSDR /fru BTP_BMC.fru
   For S1200BTM:
        FRUSDR /fru BTP_BMC_RM.fru

4. Now execute the following command to bring up the main FRU/SDR load menu:

    FRUSDR /cfg master.cfg


5. Select the option which is applicable to what you want to do. On a brand
   new baseboard I would highly recommend to run option 3 to program both
   the FRU and SDR. By reprogramming the FRU you will be given the option
   to input data from the keyboard into various chassis, board and product
   areas. Ensure that you select the correct chassis from the chassis
   selection menu otherwise your fan sensors will not be configured
   properly.

6. Once the package has finished its installation, I would highly recommend
   to DC power off the system and cycle AC power.

=============================================================================
                           KNOWN ISSUES/WORKAROUNDS
=============================================================================

- Abnormal LNC event for Vccp may be seen with Intel(R) Xeon(R) E3-1200V2 and 
the 3rd Generation Intel(R) Core(TM) i3 CPU ES2 sample until QS sample, 
because VCCIO_SEL# pin on the CPU will not report 1.05V. 
  

=============================================================================
                           FEATURES ADDED
=============================================================================
1.16:
- Update FRUSDR utility to FRUSDR11.0-Build14.

1.15:
- Support Board S1200BTLRM.
- Update FRUSDR utility to FRUSDR11.0-Build12.


1.14:
- Add PV_VCC_SENSOR(0xE0) to support Intel(R) Xeon(R) E3-1200V2 Processors.
- Correct the comment for BB +3V Vbat record.

1.13:
- Add different stepping to support Intel(R) Xeon(R) E3-1200V2 Processors.

1.12:
- Add Intel(R) Xeon(R) E3-1200V2 Processors detection.

1.11:
- Divide sensor number 04h record into two, one is with chassis intrusion event mask, another is not.

1.10:
- Add Front Panel NMI tag.
- Modify sensor type and event reading type for Mem P1 Thermal Trip.
- Add auto-detection for next generation processor

1.09:
- Correct fan sensor multiplier for the 3rd party chassis.
- Remove displaying the prompt if no front panel sensor is detected.

1.08:
- Modify 3V VBat upper critical/non-critical threshold value to FFh/FEh.

1.07:
- Add checking prod id mechanism.
- Correct OTHER chassis referring to front panel for stepwise.
- Modify fan speed range for 3rd party chassis.
- Update SDR as per Bromolow FSC Config Sheet.xls(v2.0).
- Change display for board name to S1200BTL and chassis code name.
- Modify Node Manager discovery record to support Node Manager Capabilities 
  and Threshold sensor.

1.05:
- Modify entity instance for entity id 07 to identical.

1.04:
- Change P4304XXSHBN domain 3 stepwise fan speed control value.
- Change HSBP target temperature for clamping to 52 degree.
- Add an OEM Node Manager Discovery record for SDR.
- Update SDR as per Bromolow FSC Config Sheet.xls(v1.9).

1.03:
- Unique the entity instance for each entity id.
- Add a condition for CPU fan shouldn't install for R1304XXS chassis detection.
- Update FRUSDR utility to FRUSDR10.0-Build05.
- Change file name to align BMC version.

11:
- Switch sensor number for Board Inlet Temperature and iBMC Board Temperature sensor.
- Update P4304XXSFCN System Fan4.
- Remove chassis intrusion sensor for R1304XXS.

10:
- Initial FRU/SDR production release for Intel(R) Server Board S1200BTL.
=============================================================================
                           ISSUES FIXED
=============================================================================
Revision 1.15:
- None.

Revision 1.14:
- None.

Revision 1.13:
- Cannot detect "Intel(R) Xeon(R) E3-1200V2 Processors" during the processing of 
  FRUSDR update.

Revision 1.12:
- None.

Revision 1.11
 - None

Revision 1.10
 - None
 
Revision 1.09
 - None
 
Revision 1.08
 - None
 
Revision 1.07:
- FRUSDR update can be continued when product ID is not match.

Revision 1.05:
- None

Revision 1.04:
- None.

Revision 1.03:
- None

Revision 11:
- System FAN4 lower critical event is generated when issuing "Set Fan Control 
  Configuration" command.
- SDR mismatch for Sensor P1 VRD HOT.
- Temp sensors(U3A1 and U4J1) showed opposite message.

=============================================================================
                             REFERENCE MATERIAL
=============================================================================

[END OF RELEASE NOTES]