ATTENTION Make sure to back up the data on the drive before you replace it.
1.
Navigate to the Controller dashboard, click a drive group name (for example, DG_1). Click the
icon corresponding to a drive group to display its contents.
The virtual drives and physical drives associated with the selected drive group appear.
2.
Click the Physical Drive tab, and select a drive which you want to replace.
3.
Select Actions > Replace Drive.
The Replace Drive dialog appears.
4.
Select a replacement drive and click Replace Physical Drive.
A confirmation message appears.
5.
Select Confirm and click Yes, Replace Drive to proceed with the replace operation.
The drive is replaced and the data is copied to the selected component.