                          Everex STEP VL/EX and VL/E

                   EISA Configuration Utility Release Note

This     Revision: C.00 (02-01-94) for STEP VL/EX and STEP VL/E
Previous Revision: B.00 (01-10-94) for STEP VL/EX
                   B.00 (12-02-93) for STEP VL/E

Changes:

01	The same ECU diskette will support both STEP VL/EX and STEP VL/E.

02	Fix the bug that the EISA configuration utilities incorrectly display
	the onboard IDE and floppy activation status.

	Symptom:
	When the onboard IDE is enabled and the onboard floppy is disabled
	by the system BIOS, the EISA configuration utilities will incorrectly
	display the onboard floppy as enabled and the entire system board is
	deactivated. When this happens, user cannot view, modify or save
	system board settings. This problem affects the STEP VL/EX only
	since the STEP VL/E does not have onboard IDE or floppy.

	Cause:
	The EVX1698.OVL overran a buffer when processing strings.

	Fix:
	Increase string buffer size.